The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness

被引:92
作者
Doebele, Stefan [1 ]
Horn, Carsten [2 ]
Eichhorn, Stefan [2 ]
Buchholtz, Arne [1 ]
Lenich, Andreas [1 ]
Burgkart, Rainer [2 ]
Nuessler, Andreas K. [1 ]
Lucke, Martin [1 ]
Andermatt, Daniel [3 ]
Koch, Rudolf [3 ]
Stoeckle, Ulrich [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Abt Unfallchirurg, Klin Orthopadie & Unfallchirurg, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Abt Orthopadie, Klin Orthopadie & Unfallchirurg, D-81675 Munich, Germany
[3] Synthes GmbH, Oberdorf, Switzerland
关键词
Locking compression plate; Locking screws; Dynamic locking screw; Interfragmentary motion; Stiffness reduction; BIOMECHANICAL EVALUATION; MECHANICAL STIMULATION; FRACTURE FIXATION; MICROMOVEMENT; DYNAMIZATION; BONE;
D O I
10.1007/s00423-010-0636-z
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
The plate-screw interface of an angular stable plate osteosynthesis is very rigid. So far, all attempts to decrease the stiffness of locked plating construct, e.g. the bridged plate technique, decrease primarily the bending stiffness. Thus, the interfragmentary motion increases only on the far cortical side by bending the plate. To solve this problem, the dynamic locking screw (DLS) was developed. Comparison tests were performed with locking screws (LS) and DLS. Axial stiffness, bending stiffness and interfragmentary motion were compared. For measurements, we used a simplified transverse fracture model, consisting of POM C and an 11-hole LCP3.5 with a fracture gap of 3 mm. Three-dimensional fracture motion was detected using an optical measurement device (PONTOS 5 M/GOM) consisting of two CCD cameras (2,448 x 2,048 pixel) observing passive markers. The DLS reduced the axial stiffness by approximately 16% while increasing the interfragmentary motion at the near cortical side significantly from 282 A mu m (LS) to 423 A mu m (DLS) applying an axial load of 150 N. The use of DLS reduces the stiffness of the plate-screw interface and thus increases the interfragmentary motion at the near cortical side without altering the advantages of angular stability and the strength.
引用
收藏
页码:421 / 428
页数:8
相关论文
共 27 条
[1]
Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]
[Anonymous], INJURY S2
[3]
Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength [J].
Bottlang, Michael ;
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1985-1994
[4]
Brighton C T, 1984, Instr Course Lect, V33, P60
[5]
EFFECT OF DYNAMIZATION ON GAP HEALING OF DIAPHYSEAL FRACTURES UNDER EXTERNAL FIXATION [J].
CLAES, LE ;
WILKE, HJ ;
AUGAT, P ;
RUBENACKER, S ;
MARGEVICIUS, KJ .
CLINICAL BIOMECHANICS, 1995, 10 (05) :227-234
[6]
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[7]
Early Dynamization by Reduced Fixation Stiffness Does Not Improve Fracture Healing in a Rat Femoral Osteotomy Model [J].
Claes, Lutz ;
Blakytny, Robert ;
Goeckelmann, Melanie ;
Schoen, Marcus ;
Ignatius, Anita ;
Willie, Bettina .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (01) :22-27
[8]
Duda GN, 2002, CLIN ORTHOP RELAT R, P163
[9]
Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[10]
Stiffness Modulation of Locking Plate Constructs Using Near Cortical Slotted Holes: A Preliminary Study [J].
Gardner, Michael J. ;
Nork, Sean E. ;
Huber, Phillipe ;
Krieg, James C. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (04) :281-287