MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses

被引:49
作者
Ayuso, JR
de Caralt, TM
Pages, M
Riambau, V
Ayuso, C
Sanchez, M
Real, MI
Montaña, X
机构
[1] Hosp Clin Barcelona, Ctr Diagnost, Imatge Clin, E-08036 Barcelona, Spain
[2] Hosp Clin Barcelona, Inst Clin Malalties Cardiovasc, E-08036 Barcelona, Spain
关键词
abdominal aortic aneurysms; magnetic resonance angiography; computed tomography angiography; endoprosthesis;
D O I
10.1002/jmri.20170
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate whether MR angiography (MRA) is a useful tool for the follow-up of aortic aneurysms treated with nitinol endoluminal grafts. Materials and Methods: We examined 28 patients treated with nitinol endovascular stents to repair an aortic aneurysm with CT angiography (CTA) and MRA. Eleven patients (group 1) underwent an MRA after a positive CTA for endoleak was observed. Afterwards, 17 patients (group 2) were scheduled for both follow-up examinations. The kind of endoleak that occurred and the maximum aortic diameter were compared. The sensitivity of CTA relative to MRA for detecting endoleaks in group 2 was calculated. Signal-to-noise ratios (SNRs) were measured in the aortoiliac lumen at the arterial phase in, above, and below the endoprostheses. Student's t-test was used to compare aneurysm dimensions and SNR measurements. Results: Three type III leaks were correctly assessed at both examinations; however, CTA was less sensitive (50%) than MRA in depicting type II or unclassified leaks. No differences in aneurismal size were observed between the two examinations or between arterial SNRs observed in or out of the devices. Conclusion: MRA can provide all relevant information necessary for the follow-up of patients treated with nitinol endoprostheses, and performs better than CTA in detecting endoleaks. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 21 条
  • [1] Aortic aneurysmal disease: Assessment of stent-graft treatment - CT versus conventional angiography
    Armerding, MD
    Rubin, GD
    Beaulieu, CF
    Slonim, SM
    Olcott, EW
    Samuels, SL
    Jorgensen, MJ
    Semba, CP
    Jeffrey, RB
    Dake, MD
    [J]. RADIOLOGY, 2000, 215 (01) : 138 - 146
  • [2] MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms
    Cejna, M
    Loewe, C
    Schoder, M
    Dirisamer, A
    Hölzenbein, T
    Kretschmer, G
    Lammer, J
    Thurnher, S
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (10) : 2443 - 2450
  • [3] CHAFKE N, 2004, EUR J VASC ENDOVASC, V27, P33
  • [4] Reporting standards for endovascular aortic aneurysm repair
    Chaikof, EL
    Blankensteijn, JD
    Harris, PL
    White, GH
    Zarins, CK
    Bernhard, VM
    Matsumura, JS
    May, J
    Veith, FJ
    Fillinger, MF
    Rutherford, RB
    Kent, KC
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) : 1048 - 1060
  • [5] Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms
    Engellau, L
    Larsson, EM
    Albrechtsson, U
    Jonung, T
    Ribbe, E
    Thorne, J
    Zdanowski, Z
    Norgren, L
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 212 - 219
  • [6] Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition
    Golzarian, J
    Dussaussois, L
    Abada, HT
    Gevenois, PA
    Van Gansbeke, D
    Ferreira, J
    Struyven, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 329 - 331
  • [7] Görich J, 1999, RADIOLOGY, V213, P767
  • [8] Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms
    Haulon, S
    Lions, C
    McFadden, EP
    Koussa, M
    Gaxotte, V
    Halna, P
    Beregi, JP
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 22 (01) : 62 - 69
  • [9] Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristics
    Hilfiker, PR
    Quick, HH
    Pfammatter, T
    Schmidt, M
    Debatin, JF
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (09) : 1775 - 1780
  • [10] MARREWIJK C, J VASC SURG, V35, P211