Gallamine-tetraphenylborate-modified carbon paste electrode for the potentiometric determination of gallamine triethiodide (Flaxedil)

被引:18
作者
Abbas, MN [1 ]
Mostafa, GAE [1 ]
机构
[1] Natl Res Ctr, Appl Organ Chem Dept, Microanalyt Lab, Cairo, Egypt
关键词
gallamine; tetraphenylborate; modified carbon paste electrode; pharmaceutical analysis;
D O I
10.1016/S0731-7085(02)00663-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and general performance of a novel modified carbon paste electrode for the determination of gallamine triethiodide have been developed. The electrode shows a stable, potentiometric response for gallamine in the concentration range 1 x 10(-3) -2 x 10(-6) M at 25 degreesC independent of pH in the range 5-8. The electrode passes a near-Nernstian cationic slope of 17.0+/-0.7 mV and lower detection limit of 1 x 10(-6) M with a fast response time of 20-45 s. Selectivity coefficients for gallamine relative to a number of interfering substances were investigated. There is a negligible interference from the studied cations, anions, and pharmaceutical excipients. The determination of gallamine in aqueous solution shows an average recovery of 99.5% and a mean relative standard deviation (RSD) of 1.4% at 100 mug/ml. The direct determination of gallamine in injection solution gave results that compare favorably with those obtained by the British pharmacopoeia method. Potentiometric titration of gallamine with sodium tetraphenylborate and phosphotungstic acid as a titrant has been monitored with the modified carbon paste electrode as an end-point indicator electrode. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:819 / 826
页数:8
相关论文
共 17 条
[1]   Cathodic adsorptive stripping voltammetric determination of muscle relaxant: gallamine triethiodide (flaxedil) [J].
Ali, AMM ;
Ghandour, MA ;
Abd-El-Fattah, MM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (01) :31-37
[2]   ION-SELECTIVE MEMBRANE ELECTRODES FOR THE DETERMINATION OF THE MUSCLE-RELAXANTS PANCURONIUM, TUBOCURARINE, GALLAMINE AND SUCCINYLCHOLINE [J].
AUBECK, R ;
BRAUCHLE, C ;
HAMPP, N .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :405-410
[3]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[4]   SPECTROPHOTOMETRIC DETERMINATION OF SOME PHARMACEUTICALLY IMPORTANT NITRO-COMPOUNDS IN THEIR DOSAGE FORMS [J].
HASSAN, SM ;
BELAL, F ;
ELDIN, MS ;
SULTAN, M .
ANALYST, 1988, 113 (07) :1087-1089
[5]   LIQUID AND POLYVINYL-CHLORIDE) ATROPINE REINECKATE MEMBRANE ELECTRODES FOR DETERMINATION OF ATROPINE [J].
HASSAN, SSM ;
TADROS, FS .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :542-546
[6]  
HAVERY SC, 1980, REMINGTONS PHARM SCI, P850
[7]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[8]   The detection and identification of quaternary nitrogen muscle relaxants in biological fluids and tissues by ion-trap LC-ESI-MS [J].
Kerskes, CHM ;
Lusthof, KJ ;
Zweipfenning, PGM ;
Franke, JP .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2002, 26 (01) :29-34
[9]   Cuprite-modified electrode for the detection of iodide species [J].
Lefevre, G ;
Bessiere, J ;
Walcarius, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (2-3) :113-117
[10]   SIMPLE PROCEDURE INVOLVING DERIVATIZATION AND THIN-LAYER CHROMATOGRAPHY FOR THE ESTIMATION OF TRACE LEVELS OF HALOGENATED ALKYLAMINES AND THEIR HYDROLYSIS PRODUCTS IN DRUG SUBSTANCES AND FORMULATIONS [J].
LEIGH, PH ;
BOWKER, MJ .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (01) :211-219