Comparison of two amplification technologies for detection and quantitation of human immunodeficiency virus type 1 RNA in the female genital tract

被引:21
作者
Bremer, J [1 ]
Nowicki, M
Beckner, S
Brambilla, D
Cronin, M
Herman, S
Kovacs, A
Reichelderfer, P
机构
[1] Rush Med Coll, Chicago, IL 60612 USA
[2] Univ So Calif, Los Angeles, CA 90033 USA
[3] WESTAT Corp, Rockville, MD 20850 USA
[4] New England Res Inst, Watertown, MA 02472 USA
[5] Organon Tekn Corp, Durham, NC 27712 USA
[6] Roche Mol Syst Inc, Dept Infect Dis, Alameda, CA 94501 USA
[7] NICHHD, Bethesda, MD 20892 USA
关键词
D O I
10.1128/JCM.38.7.2665-2669.2000
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Human immunodeficiency virus type 1 (HIV-1) RNA levels in female genital tract and peripheral blood samples were compared using two commercial amplification technologies: the Roche AMPLICOR HIV-1 MONITOR test and either the Organon Teknika nucleic acid sequence-based amplification (NASBA-QT) assay or the NucliSens assay. Estimates of HIV-1 RNA copy number were derived from internal kit standards and analyzed unadjusted and adjusted to a common set of external standards. We found a discordance rate of approximately 18% between the two technologies for the detection of HIV-1 in either the genital tract or peripheral blood samples. Detection discordance was not consistent among specimens or among women. There were no significant differences In adjusted or unadjusted estimates of HIV-1 RNA copy number in the genital tract samples using the AMPLICOR HIV-1 MONITOR test and either the NASBA-QT assay or the NucliSens assay, In addition, the estimated HIV-1 RNA copy number in peripheral blood samples did not differ when tested with the NucliSens assay and the AMPLICOR HIV-1 MONITOR test using kit standards. However, there was a significant difference In estimated RNA copy number between the NASBA-QT assay and the AMPLICOR HIV-1 MONITOR test for internal kit standards, which, as we have previously shown, was eliminated after adjustment with the external standards. Our results suggest that the Roche and Organon Teknika assays are equivalent for quantifying HIV-1 RNA in female genital tract specimens, although variation in detection does exist.
引用
收藏
页码:2665 / 2669
页数:5
相关论文
共 14 条
[1]   The Women's Interagency HIV Study [J].
Barkan, SE ;
Melnick, SL ;
Preston-Martin, S ;
Weber, K ;
Kalish, LA ;
Miotti, P ;
Young, M ;
Greenblatt, R ;
Sacks, H ;
Feldman, J .
EPIDEMIOLOGY, 1998, 9 (02) :117-125
[2]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[3]   Absolute copy number and relative change in determinations of human immunodeficiency virus type 1 RNA in plasma: Effect of an external standard on kit comparisons [J].
Brambilla, D ;
Leung, S ;
Lew, J ;
Todd, J ;
Herman, S ;
Cronin, M ;
Shapiro, DE ;
Bremer, J ;
Hanson, C ;
Hillyer, GV ;
McSherry, GD ;
Sperling, RS ;
Coombs, RW ;
Reichelderfer, PS .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) :311-314
[4]   Association between culturable human immunodeficiency virus type 1 (HIV-1) in semen and HIV-1 RNA levels in semen and blood: Evidence for compartmentalization of HIV-1 between semen and blood [J].
Coombs, RW ;
Speck, CE ;
Hughes, JP ;
Lee, W ;
Sampoleo, R ;
Ross, SO ;
Dragavon, J ;
Peterson, G ;
Hooton, TM ;
Collier, AC ;
Corey, L ;
Koutsky, L ;
Krieger, JN .
JOURNAL OF INFECTIOUS DISEASES, 1998, 177 (02) :320-330
[5]   Quantitation of human immunodeficiency virus type 1 RNA in cell free seminal plasma: Comparison of NASBA(TM) with Amplicor(TM) reverse transcription-PCR amplification and correlation with quantitative culture [J].
Dyer, JR ;
Gilliam, BL ;
Eron, JJ ;
Grosso, L ;
Cohen, MS ;
Fiscus, SA .
JOURNAL OF VIROLOGICAL METHODS, 1996, 60 (02) :161-170
[6]   Comparison of NucliSens and Roche monitor assays for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma [J].
Dyer, JR ;
Pilcher, CD ;
Shepard, R ;
Schock, J ;
Eron, JJ ;
Fiscus, SA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (02) :447-449
[7]   High viral load in semen of human immunodeficiency virus type 1-infected men at all stages of disease and its reduction by therapy with protease and nonnucleoside reverse transcriptase inhibitors [J].
Gupta, P ;
Mellors, J ;
Kingsley, L ;
Riddler, S ;
Singh, MK ;
Schreiber, S ;
Cronin, M ;
Rinaldo, CR .
JOURNAL OF VIROLOGY, 1997, 71 (08) :6271-6275
[8]   HIV quantitation in spiked vaginocervical secretions: lack of non-specific inhibitory factors [J].
Holodniy, M ;
Anderson, D ;
Wright, D ;
Sharma, O ;
Cohn, J ;
Alexander, N ;
Stratton, P ;
Reichelderferd, P .
JOURNAL OF VIROLOGICAL METHODS, 1998, 72 (02) :185-195
[9]   MULTICENTER EVALUATION OF QUANTIFICATION METHODS FOR PLASMA HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 RNA [J].
LIN, HJ ;
MYERS, LE ;
YENLIEBERMAN, B ;
HOLLINGER, FB ;
HENRARD, D ;
HOOPER, CJ ;
KOKKA, R ;
KWOK, S ;
RASHEED, S ;
VAHEY, M ;
WINTERS, MA ;
MCQUAY, LJ ;
NARA, PL ;
REICHELDERFER, P ;
COOMBS, RW ;
JACKSON, JB .
JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (03) :553-562
[10]   RAPID AND SIMPLE PCR ASSAY FOR QUANTITATION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 RNA IN PLASMA - APPLICATION TO ACUTE RETROVIRAL INFECTION [J].
MULDER, J ;
MCKINNEY, N ;
CHRISTOPHERSON, C ;
SNINSKY, J ;
GREENFIELD, L ;
KWOK, S .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (02) :292-300