CONTRAST AGENT KINETICS IN THE RABBIT BRAIN DURING EXPOSURE TO THERAPEUTIC ULTRASOUND

被引:42
作者
Goertz, David E. [1 ,2 ]
Wright, Cameron [2 ]
Hynynen, Kullervo [2 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
基金
美国国家卫生研究院;
关键词
Ultrasound; Microbubbles; Drug delivery; Blood-brain barrier; FOCUSED-ULTRASOUND; BARRIER DISRUPTION; TARGETED DELIVERY; QUANTIFICATION; MICROBUBBLES; PERFUSION;
D O I
10.1016/j.ultrasmedbio.2010.03.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound-stimulated microbubbles are currently under investigation as a means of transiently disrupting the blood-brain barrier (BBB) and it has been shown that the strength of this effect is highly dependent on ultrasound exposure conditions. The objective of this study was to investigate the potential for contrast agent destruction in the brain under conditions relevant to BBB disruption with a view to determining its possible influence on effective exposure parameters. An ultrasound imaging array was mounted within the aperture of a 1.68-MHz focused therapy transducer. Pulse lengths of 10 ms were used at repetition rates of 0.1-2.0 Hz and pressures from 0.30-0.88MPa. Contrast imaging was performed after the bolus injection of Definity (TM), and contrast time-intensity curves were then analyzed for regions-of-interest exposed to the therapy beam. Individual therapy pulses resulted in microbubble destruction, with the degree of agent depletion and replenishment time increasing with transmit pressure. As the pulse repetition rate was increased, agent reperfusion between pulses was incomplete and the concentration within the beam was progressively diminished, to a degree dependent on both pressure and repetition rates. These results demonstrate that microbubble concentration can be substantially influenced by destruction induced by therapeutic ultrasound pulses. The kinetics of this effect may therefore be a significant factor influencing the efficiency of BBB disruption, suggesting that monitoring of the spatial and temporal distribution of contrast agents may be warranted to guide and optimize BBB disruption therapy in both preclinical and clinical contexts. (E-mail: goertz@sri.utoronto.ca) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:916 / 924
页数:9
相关论文
共 27 条
[1]  
[Anonymous], Scaling: Why is Animal Size So Important?
[2]   A new formalism for the quantification of tissue perfusion by the destruct ion-replenishment method in contrast ultrasound Imaging [J].
Arditi, Marcel ;
Frinking, Peter J. A. ;
Zhou, Xiang ;
Rognin, Nicolas G. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (06) :1118-1129
[3]   Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow [J].
Broumas, AR ;
Pollard, RE ;
Bloch, SH ;
Wisner, ER ;
Griffey, S ;
Ferrara, KW .
INVESTIGATIVE RADIOLOGY, 2005, 40 (03) :134-147
[4]   Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound [J].
Choi, J. J. ;
Pernot, M. ;
Brown, T. R. ;
Small, S. A. ;
Konofagou, E. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18) :5509-5530
[5]   Mechanisms of contrast agent destruction [J].
Chomas, JE ;
Dayton, P ;
Allen, J ;
Morgan, K ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :232-248
[6]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[7]  
Hudson JM, 2006, ULTRASON, P1588
[8]   500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls [J].
Hynynen, K ;
Clement, GT ;
McDannold, N ;
Vykhodtseva, N ;
King, R ;
White, PJ ;
Vitek, S ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :100-107
[9]   Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits [J].
Hynynen, K ;
McDannold, N ;
Vykhodtseva, N ;
Jolesz, FA .
RADIOLOGY, 2001, 220 (03) :640-646
[10]  
Hynynen K., 2008, MRI GUIDED FOCUSED U