A mediator-type biosensor as a new approach to biochemical oxygen demand estimation

被引:82
作者
Yoshida, N
Yano, K
Morita, T
McNiven, SJ
Nakamura, H
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Akebono Brake Res & Dev Ctr, Hanyu, Saitama 3480051, Japan
关键词
D O I
10.1039/b005995l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel biosensor for the determination of biochemical oxygen demand (BOD) was developed using potassium hexacyanoferrate(iii) [HCF(iii)] as a mediator. The sensor element consists of a three-electrode system, with both working and counter electrodes compactly integrated as a disposable using etching and electroplating processes. Pseudomonas fluorescens biovar V (isolated from a wastewater treatment plant) was immobilized on the surface of the working electrode using poly(vinyl alcohol)-quaternized stilbazol (PVA-SbQ) photopolymer gel. Synthetic wastewater described by the Organization for Economic Cooperation and Development (OECD) was used as a standard solution instead of glucose-glutamic acid synthetic wastewater. The conditions of amperometric measurement were optimized at +600 mV (vs. Ag/AgCl) operating potential, namely 40 mM HCF(iii) in a 0.1 M phosphate buffer (pH 7.0) at 20 degreesC. The sensor response was linear from 15 up to 200 mg O l(-1) BOD. The response time was 15 min at 200 mg O l(-1) BOD. To demonstrate the wide metabolic range of activity of the sensor, the sensor response to 14 substances in four categories of organic compounds was investigated. Further, it was shown that the response of this BOD sensor was not influenced in samples with low concentrations of dissolved oxygen under the measuring conditions used. For real wastewaters, the BOD values were determined using the sensor and compared favorably with those determined by the conventional BOD5 method.
引用
收藏
页码:2280 / 2284
页数:5
相关论文
共 35 条
[21]   An organic pollution sensor based on surface photovoltage [J].
Murakami, Y ;
Kikuchi, T ;
Yamamura, A ;
Sakaguchi, T ;
Yokoyama, K ;
Ito, Y ;
Takiue, M ;
Uchida, H ;
Katsube, T ;
Tamiya, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (03) :163-172
[22]   DYE-COUPLED ELECTRODE SYSTEM FOR THE RAPID-DETERMINATION OF CELL-POPULATIONS IN POLLUTED WATER [J].
NISHIKAWA, S ;
SAKAI, S ;
KARUBE, I ;
MATSUNAGA, T ;
SUZUKI, S .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (04) :814-818
[23]  
*ORG EC CORP DEV, 1991, OECD GUID TEST CHEM, V209, P1
[24]   DEVELOPMENT OF AN ELECTROCHEMICAL METHOD FOR THE RAPID-DETERMINATION OF MICROBIAL CONCENTRATION AND EVIDENCE FOR THE REACTION-MECHANISM [J].
RAMSAY, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) :61-69
[25]   Rapid and direct determination of wastewater BOD values using a fluorescence technique [J].
Reynolds, DM ;
Ahmad, SR .
WATER RESEARCH, 1997, 31 (08) :2012-2018
[26]  
RIEDEL K, 1988, APPL MICROBIOL BIOT, V28, P316
[27]  
Riedel K, 1998, ANAL LETT, V31, P1
[28]  
ROLLER SD, 1984, J CHEM TECH BIOT B, V34, P3
[29]   Torulopsis candida based sensor for the estimation of biochemical oxygen demand and its evaluation [J].
Sangeetha, S ;
Sugandhi, G ;
Murugesan, M ;
Madhav, VM ;
Berchmans, S ;
Rajasekar, R ;
Rajasekar, S ;
Jeyakumar, D ;
Rao, GP .
ELECTROANALYSIS, 1996, 8 (07) :698-701
[30]  
SHEATH PHA, 1986, BERGEYS MANUAL SYSTE