Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies

被引:19
作者
Di Bella, EVR
Wu, YJ
Alexander, AL
Parker, DL
Green, D
McGann, CJ
机构
[1] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Psychiat, Madison, WI 53706 USA
关键词
UNFOLD; temporal filtering; myocardial perfusion imaging; gadolinium; rapid imaging;
D O I
10.1002/mrm.10439
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic contrast myocardial perfusion studies may benefit from methods that speed up the acquisition. Unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD), and a similar linear interpolation method have been shown to be effective at reducing the number of phase encodes needed for cardiac wall motion studies by using interleaved sampling and temporal filtering. Here such methods are evaluated in cardiac dynamic contrast studies, with particular regard to the effects of the choice of filter and the interframe motion. Four different filters were evaluated using a motion-free canine study. Full k-space was acquired and then downsampled to allow for a measure of truth. The different filters gave nearly equivalent images and quantitative flow estimates compared to full k-space. The effect of respiratory motion on these schemes was graphically depicted, and the performance of the four temporal filters was evaluated in seven human subjects with respiratory motion present. The four filters provided images of similar quality. However, none of the filters were effective at eliminating motion artifacts. Motion registration methods or motion-free acquisitions may be necessary to make these reduced FOV approaches clinically useful. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:895 / 902
页数:8
相关论文
共 21 条
  • [1] Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance
    Al-Saadi, N
    Nagel, E
    Gross, M
    Bornstedt, A
    Schnackenburg, B
    Klein, C
    Klimek, W
    Oswald, H
    Fleck, E
    [J]. CIRCULATION, 2000, 101 (12) : 1379 - 1383
  • [2] Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage
    Bertschinger, KM
    Nanz, D
    Buechi, M
    Luescher, TF
    Marincek, B
    von Schulthess, GK
    Schwitter, J
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) : 556 - 562
  • [3] DIBELLA EVR, 2002, P 10 ANN M ISMRM HON
  • [4] Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    Ding, SJ
    Wolff, SD
    Epstein, FH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 514 - 519
  • [5] EPSTEIN FH, 2000, P RSNA CHIC
  • [6] Haacke E. M., 1999, MAGNETIC RESONANCE I
  • [7] Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    Kellman, P
    Epstein, FH
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 846 - 852
  • [8] Madore B, 1999, MAGNET RESON MED, V42, P813, DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO
  • [9] 2-S
  • [10] Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO