Development of robust multivariate calibration models

被引:31
作者
Thomas, EV
Ge, NX
机构
[1] Sandia Natl Labs, Stat & Human Factors Dept, Albuquerque, NM 87185 USA
[2] Bristol Myers Squibb, Princeton, NJ 08543 USA
关键词
calibration maintenance; chemometrics; diffuse reflectance spectroscopy; robust experimental design; signal-response system;
D O I
10.2307/1271449
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Multivariate calibration is frequently used for the quantitative analysis of a wide variety of materials using spectroscopy in the agricultural and food industries, manufacturing industries, medical sciences, and pharmaceutical industries. To date, most of the research activities in the multivariate calibration literature have focused on data analysis for model building and prediction with methods such as principal-components regression or partial least squares regression. As an alternative to focusing on data-analytic activities, we consider the ability of an experimental design to improve the robustness of the resulting calibration model. Through an example involving diffuse reflectance measurements, we illustrate how consideration of environmental and instrumental factors during the experimental design phase can result in a calibration model that is robust (against natural environmental and instrument variations) and easy to maintain. In this example, the analyte of interest produces a spectroscopic signal that is very weak in comparison to the environmental and instrumental factors.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 21 条
  • [11] Non-invasive monitoring of metabolites using near infrared spectroscopy: State of the art
    Heise, HM
    [J]. HORMONE AND METABOLIC RESEARCH, 1996, 28 (10) : 527 - 534
  • [12] KACKAR RN, 1985, J QUAL TECHNOL, V17, P176, DOI 10.1080/00224065.1985.11978964
  • [13] Miller A, 1996, STAT SCI, V11, P122
  • [14] COMPARISON OF LINEAR STATISTICAL-METHODS FOR CALIBRATION OF NIR INSTRUMENTS
    NAES, T
    IRGENS, C
    MARTENS, H
    [J]. APPLIED STATISTICS-JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES C, 1986, 35 (02): : 195 - 206
  • [15] NAES T, 1985, TECHNOMETRICS, V27, P301
  • [16] TAGUCHI PARAMETER DESIGN - A PANEL DISCUSSION
    NAIR, VN
    ABRAHAM, B
    MACKAY, J
    BOX, G
    KACKER, RN
    LORENZEN, TJ
    LUCAS, JM
    MYERS, RH
    VINING, GG
    NELDER, JA
    PHADKE, MS
    SACKS, J
    WELCH, WJ
    SHOEMAKER, AC
    TSUI, KL
    TAGUCHI, S
    WU, CFJ
    [J]. TECHNOMETRICS, 1992, 34 (02) : 127 - 161
  • [17] ESTIMATING FETAL AGE BY ULTRASOUND MEASUREMENTS - AN EXAMPLE OF MULTIVARIATE CALIBRATION
    OMAN, SD
    WAX, Y
    [J]. BIOMETRICS, 1984, 40 (04) : 947 - 960
  • [18] SMITH RL, 1987, APPL STAT-J ROY ST C, V36, P283
  • [19] ERRORS-IN-VARIABLES ESTIMATION IN MULTIVARIATE CALIBRATION
    THOMAS, EV
    [J]. TECHNOMETRICS, 1991, 33 (04) : 405 - 413
  • [20] COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR QUANTITATIVE SPECTRAL-ANALYSIS
    THOMAS, EV
    HAALAND, DM
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (10) : 1091 - 1099