Enantioselective sensors based on antibody-mediated nanomechanics

被引:78
作者
Dutta, P
Tipple, CA
Lavrik, NV
Datskos, PG
Hofstetter, H
Hofstetter, O
Sepaniak, MJ [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[3] No Illinois Univ, Dept Chem & Biochem, De Kalb, IL 60115 USA
关键词
D O I
10.1021/ac034031z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of microfabricated cantilevers as bioaffinity sensors was investigated. Since many bioaffinity interactions involve proteins as receptors, we conducted studies of the magnitude, kinetics, and reversibility of surface stresses caused when common proteins interact with microcantilevers (MCs) with nanostructured (roughened) gold surfaces on one side. Exposure of nanostructured, unfunctionalized MCs to the proteins immunoglobulin G and bovine serum albumin (BSA) resulted in reversible large tensile stresses, whereas MCs with smooth gold surfaces on one side produced reversible responses that were considerably smaller and compressive. The response magnitude for nanostructured MCs exposed to BSA is shown to be concentration dependent, and linear calibration over the range of 1-200 mg/L is demonstrated. Stable, reusable protein bioaffinity phases based on unique enantioselective antibodies are created by co-valently linking monoclonal antibodies to nanostructured MC surfaces. The direct (label-free) stereoselective detection of trace amounts of an important class of chiral analytes, the a-amino acids, was achieved based on immunomechanical responses involving nanoscale bending of the cantilever. The temporal response of the cantilever (Delta deflection/Delta time) is linearly proportional to the analyte concentration and allows the quantitative determination of enantiomeric purity up to an enantiomeric excess of 99.8%. To our knowledge, this is the first demonstration of chiral discrimination using highly scalable microelectromechanical systems.
引用
收藏
页码:2342 / 2348
页数:7
相关论文
共 34 条
  • [1] Molecularly imprinted polymers for bioanalysis: Chromatography, binding assays and biomimetic sensors
    Ansell, RJ
    Kriz, D
    Mosbach, K
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) : 89 - 94
  • [2] Surface stress in the self-assembly of alkanethiols on gold
    Berger, R
    Delamarche, E
    Lang, HP
    Gerber, C
    Gimzewski, JK
    Meyer, E
    Guntherodt, HJ
    [J]. SCIENCE, 1997, 276 (5321) : 2021 - 2024
  • [3] Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films
    Betts, TA
    Tipple, CA
    Sepaniak, MJ
    Datskos, PG
    [J]. ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 89 - 99
  • [4] Chiral discrimination using piezoelectric and optical gas sensors
    Bodenhofer, K
    Hierlemann, A
    Seemann, J
    Gauglitz, G
    Koppenhoefer, B
    Gopel, W
    [J]. NATURE, 1997, 387 (6633) : 577 - 580
  • [5] ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS
    CHEN, GY
    THUNDAT, T
    WACHTER, EA
    WARMACK, RJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) : 3618 - 3622
  • [6] COOK CE, 1988, DRUG STEREOCHEMISTRY, pCH3
  • [7] Photomechanical chemical microsensors
    Datskos, PG
    Sepaniak, MJ
    Tipple, CA
    Lavrik, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3): : 393 - 402
  • [8] THE FDA PERSPECTIVE ON THE DEVELOPMENT OF STEREOISOMERS
    DECAMP, WH
    [J]. CHIRALITY, 1989, 1 (01) : 2 - 6
  • [9] Modification of micro-cantilever sensors with sol-gels to enhance performance and immobilize chemically selective phases
    Fagan, BC
    Tipple, CA
    Xue, ZL
    Sepaniak, MJ
    Datskos, PG
    [J]. TALANTA, 2000, 53 (03) : 599 - 608
  • [10] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318