A new SIMS paradigm for 2D and 3D molecular imaging of bio-systems

被引:81
作者
Fletcher, John S. [1 ]
Vickerman, John C. [1 ]
机构
[1] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
SIMS; Imaging mass spectrometry; Depth profiling; 2D imaging; 3D imaging; ION MASS-SPECTROMETRY; TOF-SIMS; BRAIN-TISSUE; CLUSTER IMPACTS; C-60; BUCKMINSTERFULLERENE; EMISSION; CELLS; LOCALIZATION; SUPPRESSION;
D O I
10.1007/s00216-009-2986-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With the implementation of focused primary ion beams, secondary ion mass spectrometry (SIMS) has become a significant technique in the rapidly emerging field of mass spectral imaging in the biological sciences. Liquid metal ion guns (LMIG) offered the prospect of sub-100 nm spatial resolution, however this aspiration has yet to be reached for molecular imaging. This brief review shows that using LMIG the limitations of the static limit and low ionization probability will restrict useful imaging to around 2 mu m spatial resolution with high-yield molecules. The only prospect of going beyond this in the absence of factors of 100 increase in ionization probability is to use polyatomic ion beams such as C (60) (+) , for which bombardment induced damage is low. In these cases sub-micron imaging becomes possible, using voxels together with molecular depth profiling and 3D imaging. The discussion shows that conventional ToF-SIMS instrumentation then becomes a limitation in that the pulsed ion beam has a very low duty cycle which results in inordinately long analysis times, and pulsing the beam means that high-mass resolution and high spatial resolution are mutually incompatible. New instrumental configurations are described that allow the use of a dc ion beam and separate the mass spectrometry for the ion formation process. Early results from these instruments suggest that sub-micron analysis and imaging with high mass resolution and good ion yields are now realizable, although the low ion yield issue still needs to be solved.
引用
收藏
页码:85 / 104
页数:20
相关论文
共 51 条
[1]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[2]  
Braun RM, 1998, RAPID COMMUN MASS SP, V12, P1246, DOI 10.1002/(SICI)1097-0231(19980930)12:18<1246::AID-RCM316>3.0.CO
[3]  
2-C
[4]   The chemical composition of animal cells and their intracellular compartments reconstructed from 3D mass spectrometry [J].
Breitenstein, Daniel ;
Rommel, Christina E. ;
Moellers, Rudolf ;
Wegener, Joachim ;
Hagenhoff, Birgit .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (28) :5332-5335
[5]   C60 Secondary Ion Mass Spectrometry with a Hybrid-Quadrupole Orthogonal Time-of-Flight Mass Spectrometer [J].
Carado, Anthony ;
Passarelli, M. K. ;
Kozole, Joseph ;
Wingate, J. E. ;
Winograd, Nicholas ;
Loboda, A. V. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :7921-7929
[6]   Molecular depth profiling with cluster ion beams [J].
Cheng, J ;
Wucher, A ;
Winograd, N .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (16) :8329-8336
[7]   Depth profiling of peptide films with TOF-SIMS and a C60 probe [J].
Cheng, J ;
Winograd, N .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3651-3659
[8]   Probing cell chemistry with time-of-flight secondary ion mass spectrometry: development and exploitation of instrumentation for studies of frozen-hydrated biological material [J].
Cliff, B ;
Lockyer, N ;
Jungnickel, H ;
Stephens, G ;
Vickerman, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (19) :2163-2167
[9]   Is proton cationization promoted by polyatomic primary ion bombardment during time-of-flight secondary ion mass spectrometry analysis of frozen aqueous solutions? [J].
Conlan, XA ;
Lockyer, NP ;
Vickerman, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (08) :1327-1334
[10]   Development and experimental application of a gold liquid metal ion source [J].
Davies, N ;
Weibel, DE ;
Blenkinsopp, P ;
Lockyer, N ;
Hill, R ;
Vickerman, JC .
APPLIED SURFACE SCIENCE, 2003, 203 :223-227