Quantitative microbial risk assessment model for Legionnaires' disease: Assessment of human exposures for selected spa outbreaks

被引:55
作者
Armstrong, Thomas W.
Haas, Charles N.
机构
[1] ExxonMobil Biomed Sci Inc, Occupat & Publ Hlth Div, Annandale, NJ 08801 USA
[2] Drexel Univ, Dept Civil Environm & Architectural Engn, Philadelphia, PA 19104 USA
关键词
exposure assessment; Legionella; legionellosis; Legionnaires' disease; QMRA; quantitative microbial risk assessment;
D O I
10.1080/15459620701487539
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Evaluation of a quantitative microbial risk assessment (QMRA) model for Legionnaires' disease (LD) required Legionella exposure estimates for several well-documented LD outbreaks. Reports for a whirlpool spa and two natural spring spa outbreaks provided data for the exposure assessment, as well as rates of infection and mortality. Exposure estimates for the whirlpool spa outbreak employed aerosol generation, water composition, exposure duration data, and building ventilation parameters with a two-zone model. Estimates for the natural hot springs outbreaks used bacterial water to air partitioning coefficients and exposure duration information. The air concentration and dose calculations used input parameter distributions with Monte Carlo simulations to estimate exposures as probability distributions. The assessment considered two sets of assumptions about the transfer of Legionella from the water phase to the aerosol emitted from the whirlpool spa. The estimated air concentration near the whirlpool spa was 5 to 18 colony forming units per cubic meter (CFU/m(3)) and 50 to 180 CFU/m(3) for each of the alternate assumptions. The estimated 95th percentile ranges of Legionella dose for workers within 15 m of the whirlpool spa were 0.13-3.4 CFU and 1.3-34.5 CFU, respectively. The modeling for hot springs Spas I and 2 resulted in estimated arithmetic mean air concentrations of 360 and 17 CFU/m(3), respectively, and 95 percentile ranges for Legionella dose of 28 to 67 CFU and 1.1 to 3.7 CFU, respectively. The Legionella air concentration estimates fall in the range of limited reports on air concentrations of Legionella (0.33 to 190 CFU/m(3)) near showers, aerated faucets, and baths during filling with Legionella-contaminated water. These measurements may provide some indication that the estimates are of a reasonable magnitude, but they do not clarify the exposure estimates accuracy, since they were not obtained during LD outbreaks. Further research to improve the data used for the Legionella exposure assessment would strengthen the results. Several of the primary additional data needs include improved data for bacterial water to air partitioning coefficients, better accounting of time-activity-distance patterns and exposure potential in outbreak reports, and data for Legionella containing aerosol viability decay instead of loss of capability for growth in culture.
引用
收藏
页码:634 / 646
页数:13
相关论文
共 98 条
[21]   AEROSOLS CONTAINING LEGIONELLA-PNEUMOPHILA GENERATED BY SHOWER HEADS AND HOT-WATER FAUCETS [J].
BOLLIN, GE ;
PLOUFFE, JF ;
PARA, MF ;
HACKMAN, B .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (05) :1128-1131
[22]   EXPOSURE TO LEGIONELLACEAE AT A HOT-SPRING SPA - A PROSPECTIVE CLINICAL AND SEROLOGICAL STUDY [J].
BORNSTEIN, N ;
MARMET, D ;
SURGOT, M ;
NOWICKI, M ;
ARSLAN, A ;
ESTEVE, J ;
FLEURETTE, J .
EPIDEMIOLOGY AND INFECTION, 1989, 102 (01) :31-36
[23]  
BORNSTEIN N, 1989, EPIDEMIOL INFECT, V102, P541
[24]   Subclinical Legionella infection in workers near the source of a large outbreak of legionnaires disease [J].
Boshuizen, HC ;
Neppelenbroek, SE ;
van Vliet, H ;
Schellekens, JFP ;
den Boer, JW ;
Peeters, MF ;
Conyn-van Spaendonck, MAE .
JOURNAL OF INFECTIOUS DISEASES, 2001, 184 (04) :515-518
[25]  
BOSHUIZEN HC, 2000, 213690006 RIVM
[26]   ASSOCIATION OF SHOWER USE WITH LEGIONNAIRES-DISEASE - POSSIBLE ROLE OF AMEBAS [J].
BREIMAN, RF ;
FIELDS, BS ;
SANDEN, GN ;
VOLMER, L ;
MEIER, A ;
SPIKA, JS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (21) :2924-2926
[27]  
*CIB, 2004, PERF CRIT BUILD HLTH
[28]  
COLBOURNE JS, 1987, LANCET, V1, P684
[29]   Correlation between Legionella contamination in water and surrounding air [J].
Crimi, Paolo ;
Macrina, Gianni ;
Grieco, Antonio ;
Tinteri, Carola ;
Copello, Laura ;
Rebora, Daniela ;
Galli, Angelo ;
Rizzetto, Rolando .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (07) :771-773
[30]   An outbreak of Legionnaire's disease among visitors to a fair in Belgium in 1999 [J].
De Schrijver, K ;
Dirven, K ;
Van Bouwel, K ;
Mortelmans, L ;
Van Rossom, P ;
De Beukelaar, T ;
Vael, C ;
Fajo, M ;
Ronveaux, O ;
Peeters, MF ;
Van der Zee, A ;
Bergmans, A ;
Leven, M ;
Goossens, H .
PUBLIC HEALTH, 2003, 117 (02) :117-124