This paper proposes a new direct power control (DPC) strategy for a doubly fed induction generator (DFIG)-based wind turbine system. The required rotor control voltage, which eliminates active and reactive power errors within each fixed time period, is directly calculated based on stator flux, rotor position, and active and reactive powers and their corresponding errors. No extra power or current control loops are required, simplifying the system design, and improving transient performance. Constant converter switching frequency is achieved that eases the design of the power converter and the ac harmonic filter. Rotor voltage limit during transients is investigated, and a scheme is proposed that prioritizes the active and reactive power control such that one remains fully controlled while the error of the other is reduced. The impact of machine parameter variations on system performance is investigated and found negligible. Simulation results for a 2 MW DFIG system demonstrate the effectiveness and robustness of the proposed control strategy during variations of active and reactive power, machine parameters, and wind speed.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 23 条
[1]   Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system [J].
Akagi, H ;
Sato, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (01) :109-116
[2]  
[Anonymous], P POW CONV C TOK JAP
[3]   DIRECT SELF-CONTROL (DSC) OF INVERTER-FED INDUCTION MACHINE - A BASIS FOR SPEED CONTROL WITHOUT SPEED MEASUREMENT [J].
BAADER, U ;
DEPENBROCK, M ;
GIERSE, G .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (03) :581-588
[4]   ADVANCED REGULAR-SAMPLED PWM CONTROL TECHNIQUES FOR DRIVES AND STATIC POWER CONVERTERS [J].
BOWES, SR .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1995, 42 (04) :367-373
[5]  
CASADEI D, 1994, IEEE IND ELEC, P299, DOI 10.1109/IECON.1994.397792
[6]  
Depenbrock M., 1988, IEEE Transactions on Power Electronics, V3, P420, DOI 10.1109/63.17963
[7]   Analysis and design of direct power control (DPC) for a three phase synchronous rectifier via output regulation subspaces [J].
Escobar, G ;
Stankovic, AM ;
Carrasco, JM ;
Galván, E ;
Ortega, R .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (03) :823-830
[8]  
Gokhale K. P., 2002, US, Patent No. 6448735
[9]   DIRECT TORQUE CONTROL OF INDUCTION MACHINES USING SPACE VECTOR MODULATION [J].
HABETLER, TG ;
PROFUMO, F ;
PASTORELLI, M ;
TOLBERT, LM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (05) :1045-1051
[10]   Direct torque control of induction machines with constant switching frequency and reduced torque ripple [J].
Idris, NRN ;
Yatim, AHM .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (04) :758-767