Flow injection potentiometric detection of trimethylamine in seafood using tungsten oxide electrode

被引:28
作者
Adhoum, N
Monser, L
Sadok, S
El-Abed, A
Greenway, GM
Uglow, RF
机构
[1] Inst Natl Sci Appl & Technol, Dept Chim, Tunis 1080, Tunisia
[2] Inst Natl Sci & Technol Mer, Salammbo 2025, Tunisia
[3] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
[4] Univ Hull, Dept Appl Biol, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
flow injection; gas diffusion; tungsten oxide electrode; trimethylamine; seafood extract;
D O I
10.1016/S0003-2670(02)01431-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple flow injection gas/diffusion method for the determination of trimethylamine (TMA) in seafood with potentiometric detection using tungsten oxide electrode has been developed. The method is based on the diffusion of TMA through a PTFE membrane from a sodium hydroxide donor stream to a phosphate buffer acceptor stream. The TMA in the acceptor stream passes through an electrochemical flow cell containing a tungsten oxide wire and a silver/silver chloride electrode, where TMA was sensitively detected. The parameters affecting the sensitivity of the electrode such as sodium hydroxide concentration, buffer concentration, pH, flow rate and injected volume were studied in details. The electrode response was linear in the concentration range from 1 to 10 mug ml(-1) TMA with a correlation coefficient (R-2) of 0.991 and a detection limit of 0.05 mug ml(-1) TMA. The intra- and inter-days precision (R.S.D.) was found to be, respectively, 1.20 and 1.6% (n = 6). The method was applied to the determination of TMA in fish tissue and recoveries of 99-100% were obtained for fish extracts. Results were in close agreement with those obtained by the existing classical official method. Common interference from those species that can diffuse through the membrane were removed by the addition of formaldehyde to the seafood extract. The method is simple, feasible with satisfactory accuracy and precision and thus, could be used for monitoring seafood quality with a sampling rate of 20 +/- 2 sample h(-1). (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 14 条
[1]  
[Anonymous], 1995, AOAC OFFICIAL METHOD, P7
[2]   Trimethylamine and total volatile basic nitrogen determination by flow injection/gas diffusion in mediterranean hake (Merluccius merluccius) [J].
Baixas-Nogueras, S ;
Bover-Cid, S ;
Vidal-Carou, MC ;
Veciana-Nogués, MT ;
Mariné-Font, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (04) :1681-1686
[3]   Potentiometric detection of carboxylic acids by flow injection analysis using a tungsten oxide electrode [J].
Chen, ZL ;
Alexander, PW .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :187-192
[4]  
CLINCH JR, 1988, THESIS U HULL
[5]  
March J., 1992, ADV ORGANIC CHEM REA, P986
[6]   Liquid chromatographic determination of methylamines. Determination of trimethylamine in fish samples using a porous graphitic carbon stationary phase [J].
Monser, LI ;
Greenway, GM .
ANALYTICA CHIMICA ACTA, 1996, 322 (1-2) :63-68
[7]  
Pivarnik LF, 1998, J AOAC INT, V81, P1011
[8]  
Ruzika J., 1981, FLOW INJECTION ANAL
[9]   Determination of trimethylamine in fish by flow injection analysis [J].
Sadok, S ;
Uglow, RF ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1996, 321 (01) :69-74
[10]  