Adaptive bone remodelling of all polyethylene unicompartmental tibial bearings

被引:11
作者
Gillies, R. Mark
Hogg, Michael C.
Kohan, Lawrence
Cordingley, Rebecca L.
机构
[1] WorleyParsons Serv Ltd, Adv Anal Grp, Sydney, NSW 2060, Australia
[2] Univ New S Wales, Grad Sch Biomed Sci, Sydney, NSW, Australia
[3] Joint Orthopaed Ctr, Sydney, NSW, Australia
关键词
bone remodelling; finite element analysis; knee; keel; polyethylene;
D O I
10.1111/j.1445-2197.2006.03980.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Failure of unicompartmental knees is either by progressive osteoarthritis or by failure of the prosthesis. Prosthesis failure can be because of either the actual component itself or its fixation method. Specifically, the tibial component may wear, loosen or subside into the tibial metaphyseal bone. We modelled all polyethylene tibial components and investigated the periprosthetic adaptive remodelling of the bone. Methods: Computed tomography scans were used to reconstruct the tibial geometry and a 3-D finite element mesh was created. The tibia loading was set at 45% of the gait cycle. The distal end of the tibia set as fixed. Implant orientations were in accordance with the manufacturer specifications. The bone mineral density changes at three regions of interest under the component were measured and plotted. Results: All regions of interest became stable at the 12-month time-point. Predictive bone mineral changes were minimal in both resorption and deposition. Zones 1-3 for the St Georg Sled (Waldermar Link, Hamburg, Germany) presented evidence of stress shielding and a maximum loss of approximately 6% bone mineral density. The Eius (Stryker Orthopaedics, Mahwah, NJ, USA) showed increased loading and caused an increase in bone mineral density for all regions of interests; the maximum being approximately 10%. Conclusion: These findings are consistent with the clinical experience of unicompartmental knee replacements, where the changes are small and have little effect on the outcome of the prosthesis. From a mechanical perspective, the results are also consistent when a compliant material is used to distribute loads. They do, however, support the biomechanical theory that a change in geometry influences the loading environment and as a consequence the adaptive response of the bone is also influenced.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 36 条
[1]
A comparative-study of the medial St Georg Sled and kinematic total knee arthroplasties - Ten-year survivorship [J].
Ackroyd, CE ;
Whitehouse, SL ;
Newman, JH ;
Joslin, CC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :667-672
[2]
St. Georg sledge for medial compartment knee replacement - 461 arthroplasties followed for 4 (1-17) years [J].
Ansari, S ;
Newman, JH ;
Ackroyd, CE .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (05) :430-434
[3]
Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis [J].
Ashraf, T ;
Newman, JH ;
Desai, VV ;
Beard, D ;
Nevelos, JE .
KNEE, 2004, 11 (03) :177-181
[4]
Lateral unicompartmental knee replacement - Survivorship and clinical experience over 21 [J].
Ashraf, T ;
Newman, JH ;
Evans, RL ;
Ackroyd, CE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08) :1126-1130
[5]
BARTLEY RE, 1994, CLIN ORTHOP RELAT R, V299, P18
[7]
Revision surgery after failed unicompartmental knee arthroplasty -: A study of 35 cases [J].
Böhm, I ;
Landsiedl, F .
JOURNAL OF ARTHROPLASTY, 2000, 15 (08) :982-989
[8]
COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[9]
Functional analysis of cemented medial unicompartmental knee arthroplasty [J].
Chassin, EP ;
Mikosz, RP ;
Andriacchi, TP ;
Rosenberg, AG .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :553-559
[10]
Châtain F, 2004, REV CHIR ORTHOP, V90, P49