Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis

被引:65
作者
Ashraf, T [1 ]
Newman, JH
Desai, VV
Beard, D
Nevelos, JE
机构
[1] Southmead Gen Hosp, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
[2] Kingsmill Hosp, Mansfield, England
[3] Corin Med, Cirencester, England
关键词
polyethylene wear; unicompartinental knee replacement; St Georg Sled;
D O I
10.1016/j.knee.2004.03.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Polyethylene wear is considered a threat to the long-term survival of unicompartmental knee replacement (UKR). This study aims to determine the linear penetration and volumetric wear associated with a non-congruent commonly used UKR, the St Georg Sled. This prosthesis has a biconvex femoral component which articulates with a flat polyethylene tibial component resulting in point contact. Components were retrieved from the knees of 19 patients undergoing revision for a failed UKR after primary replacement. Linear penetration and volumetric wear was measured using a coordinate measuring machine. Using an un-used implant, a three-dimensional computer model of the surface was generated and compared to the explanted specimen. Most patients had revisions because of disease progression to other compartments rather than specific wear related pathology. The mean linear wear for the sample was 0.89 mm (S.D. 0.59 mm) over an average period of 5.6 years giving the mean linear penetration rate of 0.15 mm/year. The mean volumetric wear was 99.7 mm(3) (S.D. 79.3 mm(3)) over the same period giving a mean annual volumetric wear rate of 17.3 mm(3)/year. The results in this study indicate that clinically significant wear is not necessarily a feature of this fixed bearing unicompartmental knee replacement. The pattern of wear is consistent with clinical findings and indicates excavation of the polyethylene after implantation but at a slower rate than would be anticipated. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 16 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]  
BARTLEY RE, 1994, CLIN ORTHOP RELAT R, P18
[3]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[4]  
KILGUS DJ, 1991, CLIN ORTHOP RELAT R, P223
[5]   Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age [J].
Kim, YH ;
Kook, HK ;
Kim, JS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (05) :770-774
[6]   Activity level and wear in total knee arthroplasty - A study of autopsy retrieved specimens [J].
Lavernia, CJ ;
Sierra, RJ ;
Hungerford, DS ;
Krackow, K .
JOURNAL OF ARTHROPLASTY, 2001, 16 (04) :446-453
[7]  
MIRRA JM, 1982, CLIN ORTHOP RELAT R, P175
[8]   TIBIAL HIGH-DENSITY POLYETHYLENE WEAR IN CONFORMING TIBIOFEMORAL PROSTHESES [J].
PLANTEBORDENEUVE, P ;
FREEMAN, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (04) :630-636
[9]  
Prudhommeaux F, 2000, CLIN ORTHOP RELAT R, P113
[10]   Wear of congruent meniscal bearings in unicompartmental knee arthroplasty - A retrieval study of 16 specimens [J].
Psychoyios, V ;
Crawford, RW ;
O'Connor, JJ ;
Murray, DW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (06) :976-982