Simultaneous determination of paracetamol, pseudoephedrine, dextrophan and chlorpheniramine in human plasma by liquid chromatography-tandem mass spectrometry

被引:90
作者
Lou, Hong-gang [1 ]
Yuan, Hong [1 ]
Ruan, Zou-rong [1 ]
Jiang, Bo [1 ]
机构
[1] Zhejiang Univ, Coll Med, Affiliated Hosp 2, Div Clin Pharmacol, Hangzhou 310009, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 7-8期
关键词
Paracetamol; Pseudoephedrine; Dextrophan; Chlorpheniramine; LC-MS/MS; Bioequivalence; QUANTIFICATION; DEXTROMETHORPHAN; URINE; DEXTRORPHAN; ASSAY;
D O I
10.1016/j.jchromb.2010.01.005
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
For the first time, a highly sensitive and simple LC-MS/MS method after one-step precipitation was developed and validated for the simultaneous determination of paracetamol (PA), pseudoephedrine (PE), dextrophan (DT) and chlorpheniramine (CP) in human plasma using diphenhydramine as internal standard (IS). The analytes and IS were separated on a YMC-ODS-AQ C-18 Column (100 mm x 2.0 mm, 3 mu m) by a gradient program with mobile phase consisting of 0.3% (v/v) acetic acid and methanol at a flow rate of 0.30 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization in the positive ion mode. The method was validated and linear over the concentration range of 10-5000 ng/mL for PA, 2-1000 ng/mL for PE, 0.05-25 ng/mL for DT and 0.1-50 ng/mL for CP. The accuracies as determined from quality control samples were in range of -8.37% to 3.13% for all analytes. Intra-day and inter-day precision for all analytes were less than 11.54% and 14.35%, respectively. This validated method was successfully applied to a randomized, two-period cross-over bioequivalence study in 20 healthy Chinese volunteers receiving multicomponent formulations containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride, 15 mg of dextromethorphan hydrobromide and 2 mg of chlorphenamine maleate. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:682 / 688
页数:7
相关论文
共 17 条
[1]
EVALUATION OF A NEW ANTITUSSIVE AGENT [J].
CASS, LJ ;
FREDERIK, WS .
NEW ENGLAND JOURNAL OF MEDICINE, 1953, 249 (04) :132-136
[2]
Simultaneous determination of paracetamol and chlorpheniramine in human plasma by liquid chromatography-tandem mass spectrometry [J].
Celma, C ;
Allué, JA ;
Pruñonosa, J ;
Peraire, C ;
Obach, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :77-86
[3]
Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography-tandem mass spectrometry [J].
Chen, XY ;
Zhang, Y ;
Zhong, DF .
BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (04) :248-253
[4]
CLARK R, 1973, LANCET, V1, P66
[5]
Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay [J].
Constanzer, ML ;
Chavez-Eng, CM ;
Fu, I ;
Woolf, EJ ;
Matuszewski, B .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2) :297-308
[6]
Eichhold TH, 1997, J MASS SPECTROM, V32, P1205
[7]
HWANG SS, 1995, J CLIN PHARMACOL, V353, P259
[8]
Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluations [J].
Ismaiel, Omnia A. ;
Halquist, Matthew S. ;
Elmamly, Magda Y. ;
Shalaby, Abdalla ;
Karnes, H. Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02) :333-343
[9]
The quantification of paracetamol, paracetamol glucuronide and paracetamol sulphate in plasma and urine using a single high-performance liquid chromatography assay [J].
Jensen, LS ;
Valentine, J ;
Milne, RW ;
Evans, AM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) :585-593
[10]
SENSITIVE QUANTIFICATION OF PSEUDOEPHEDRINE IN HUMAN-PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
NIEDER, M ;
JAEGER, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (01) :73-82