Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay

被引:25
作者
Constanzer, ML [1 ]
Chavez-Eng, CM [1 ]
Fu, I [1 ]
Woolf, EJ [1 ]
Matuszewski, B [1 ]
机构
[1] Merck Res Labs, W Point, PA 19486 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 816卷 / 1-2期
关键词
dextromethorphan; matrix effect; dextrorphan;
D O I
10.1016/j.jchromb.2004.11.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analytical method for the simultaneous determination of dextromethorphan (1) and dextrorphan (2) in urine, based on solid-phase extraction of drug from acidified hydrolyzed biological matrix, were developed. The analytes (I and 2) and the internal standard (levallorphan, 3, IS) were detected by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) in positive ionization mode using a heated nebulizer (HN) probe and monitoring their precursor --> product ion combinations of m/z 272 --> 215, 258 --> 201, and 284 --> 201 for 1, 2, and 3, respectively, in multiple reaction monitoring mode. The analytes and IS were chromatographed on a Keystone Prism reverse phase (50 mm x 2.0 mm) 5 mum column using a mobile phases consisting of a 35/65 or 27/73 mixtures of methanol/water containing 0.1% TFA adjusted to pH 3 with ammonium hydroxide pumped at 0.4 ml/min for 1 and 2, respectively. The limits of reliable quantification of 1 and 2 were 2 and 250 ng/ml, respectively, when 1 ml of urine was processed. The absence of matrix effect was demonstrated by analysis of neat standards and standards spiked into urine extracts originating from five different sources. The linear ranges of the assay were 2-200 and 250-20,000 ng/ml for 1 and 2, respectively. Assay selectivity was evaluated by monitoring the "cross-talk" effects from other metabolites into the MS/MS channels used for monitoring 1, 2, and 3. In addition, an interfering peak originating from an unknown metabolite of I into the quantification of dextromethorphan was detected, requiring an effective chromatographic separation of analytes from other metabolites of 1. The need for careful assessment of selectivity of the HPLC-MS/MS assay in the presence of metabolites, and the assessment of matrix effect, are emphasized. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:297 / 308
页数:12
相关论文
共 21 条
[1]   DETERMINATION OF DEXTROMETHORPHAN IN BIOLOGICAL-FLUIDS BY LIQUID-CHROMATOGRAPHY BY USING SEMI-MICROBORE COLUMNS [J].
ACHARI, RG ;
EDERMA, HM ;
CHIN, D ;
OLES, SR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (12) :1821-1822
[2]   High performance liquid chromatography determination of dextromethorphan and its metabolites in urine using solid-phase extraction [J].
Bartoletti, RA ;
Belpaire, FM ;
Rosseel, MT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1281-1286
[3]   GC AND GC-MS PROCEDURES FOR SIMULTANEOUS PHENOTYPING WITH DEXTROMETHORPHAN AND MEPHENYTOIN [J].
BAUMANN, P ;
JONZIERPEREY, M .
CLINICA CHIMICA ACTA, 1988, 171 (2-3) :211-222
[4]   High-performance liquid chromatography assay for simultaneous determination of dextromethorphan and its main metabolites in urine and in microsomal preparations [J].
Bendriss, EK ;
Markoglou, N ;
Wainer, IW .
JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (01) :209-215
[5]   Semi-automated liquid-liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma [J].
Bolden, RD ;
Hoke, SH ;
Eichhold, TH ;
McCauley-Myers, DL ;
Wehmeyer, KR .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01) :1-10
[6]   SIMULTANEOUS DETERMINATION OF DEXTROMETHORPHAN AND 3 METABOLITES IN PLASMA AND URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH APPLICATION TO THEIR DISPOSITION IN MAN [J].
CHEN, ZR ;
SOMOGYI, AA ;
BOCHNER, F .
THERAPEUTIC DRUG MONITORING, 1990, 12 (01) :97-104
[7]   Low level determination of a novel 4-azasteroid and its carboxylic acid metabolite in human plasma and semen using high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry [J].
Constanzer, ML ;
Chavez, CM ;
Matuszewski, BK ;
Carlin, J ;
Graham, D .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01) :117-129
[8]   DETERMINATION OF DEXTROMETHORPHAN AND METABOLITES IN HUMAN-PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
EAST, T ;
DYE, D .
JOURNAL OF CHROMATOGRAPHY, 1985, 338 (01) :99-112
[9]  
FOSSATI A, 1993, ARZNEIMITTEL-FORSCH, V43-2, P1337
[10]   Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357