Comparison of standard- and low-radiation-dose CT for quantification of emphysema

被引:62
作者
Gierada, David S. [1 ]
Pilgram, Thomas K. [1 ]
Whiting, Bruce R. [1 ]
Hong, Cheng [1 ]
Bierhals, Andrew J. [1 ]
Kim, Jin Hwan [1 ]
Bae, Kyongtae T. [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
CT technique; lung diseases;
D O I
10.2214/AJR.05.1498
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. This study was performed to compare standard- and low-radiation-dose techniques in the CT quantification of emphysema. MATERIALS AND METHODS. The study population consisted of 36 men and 20 women who were current or former heavy smokers and underwent standard- dose ( effective tube current, 100 - 250 mAs) chest CT at our institution within 6 months of having undergone low-dose ( effective tube current, 30 - 60 mAs) chest CT. All CT scans were reconstructed at 5-mm slice thickness with a smooth filter. CT-measured lung volume, mean and median lung attenuation, and percentage of lung volume with attenuation lower than multiple thresholds ( emphysema index values) were compared by Pearson correlation, two-tailed and paired Student's t tests, and regression analysis. RESULTS. There were no significant differences in mean attenuation ( - 848 vs - 846 H, p >= 0.35) for the low dose and the standard dose or in median lung attenuation ( - 879 vs - 878 H, p > 0.66). Low- and standard-dose emphysema indexes were correlated at all attenuation thresholds ( r = 0.86 - 0.97). Mean emphysema indexes were higher on the low-dose scans, but the mean difference at all thresholds was less than 3%. The differences were significant ( p < 0.05) only at the lower index thresholds, correlated with differences in lung volume ( r = 0.86), and increased with greater differences in dose. CONCLUSION. Low-dose technique has minimal effect on CT quantification of emphysema.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 27 条
[1]
Emphysema: Effect of reconstruction algorithm on CT imaging measures [J].
Boedeker, KL ;
McNitt-Gray, MF ;
Rogers, SR ;
Truong, DA ;
Brown, MS ;
Gjertson, DW ;
Goldin, JG .
RADIOLOGY, 2004, 232 (01) :295-301
[2]
A quantification of the lung surface area in emphysema using computed tomography [J].
Coxson, HO ;
Rogers, RM ;
Whittall, KP ;
D'Yachkova, Y ;
Paré, PD ;
Sciurba, FC ;
Hogg, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) :851-856
[3]
Erratum: A quantification of the lung surface area in emphysema using computed tomography [J].
Coxson, HO ;
Hogg, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (06) :1500-1501
[4]
Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers [J].
Diederich, S ;
Thomas, M ;
Semik, M ;
Lenzen, H ;
Roos, N ;
Weber, A ;
Heindel, W ;
Wormanns, D .
EUROPEAN RADIOLOGY, 2004, 14 (04) :691-702
[5]
A randomized clinical trial of α1-antitrypsin augmentation therapy [J].
Dirksen, A ;
Dijkman, JH ;
Madsen, F ;
Stoel, B ;
Hutchison, DCS ;
Ulrik, CS ;
Skovgaard, LT ;
Kok-Jensen, A ;
Rudolphus, A ;
Seersholm, N ;
Vrooman, HA ;
Reiber, JHC ;
Hansen, NC ;
Heckscher, T ;
Viskum, K ;
Stolk, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (05) :1468-1472
[6]
Comparison of computed density and microscopic morphometry in pulmonary emphysema [J].
Gevenois, PA ;
DeVuyst, P ;
deMaertelaer, V ;
Zanen, J ;
Jacobvitz, D ;
Cosio, MG ;
Yernault, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) :187-192
[7]
COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA [J].
GEVENOIS, PA ;
DEMAERTELAER, V ;
DEVUYST, P ;
ZANEN, J ;
YERNAULT, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) :653-657
[8]
Pulmonary emphysema: Comparison of preoperative quantitative CT and physiologic index values with clinical outcome after lung-volume reduction surgery [J].
Gierada, DS ;
Slone, RM ;
Bae, KT ;
Yusen, RD ;
Lefrak, SS ;
Cooper, JD .
RADIOLOGY, 1997, 205 (01) :235-242
[9]
Repeatability of quantitative CT indexes of emphysema in patients evaluated for lung volume reduction surgery [J].
Gierada, DS ;
Yusen, RD ;
Pilgram, TK ;
Crouch, L ;
Slone, RM ;
Bae, KT ;
Lefrak, SS ;
Cooper, JD .
RADIOLOGY, 2001, 220 (02) :448-454
[10]
Baseline findings of a randomized feasibility trial of lung cancer screening with spiral CT scan vs chest radiograph - The Lung Screening Study of the National Cancer Institute [J].
Gohagan, J ;
Marcus, P ;
Fagerstrom, R ;
Pinsky, P ;
Kramer, B ;
Prorok, P .
CHEST, 2004, 126 (01) :114-121