Three-electrode electrochemical detector and platinum film decoupler integrated with a capillary electrophoresis microchip for amperometric detection

被引:62
作者
Wu, CC
Wu, RG
Huang, JG
Lin, YC
Chang, HC
机构
[1] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ, Inst Engn Sci, Tainan 70101, Taiwan
关键词
D O I
10.1021/ac025912t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article demonstrates that a three-electrode electro-chemical (EC) detector and an electric decoupler could be fabricated in the same glass chip and integrated with an O-2-plasma-treated PDMS layer using microfabrication techniques to form the capillary electrophoresis (CE) microchip. The platinized decoupler could mostly decouple the electrochemical detection circuit from the interference of an separation electric field in 10 mM 2-(N-morpholino)ethanesulfonic acid (MES, pH 6.5) solution. The baseline offset of background current recorded from the working electrode with and without application of a separation electric field was maintained at less than 0.05 pA in 10 mM MES. In addition, the platinized pseudoreference electrode was demonstrated to offer a stable potential in electrochemical detection. As a consequence, the limit of detection of dopamine was 0.125 muM at a S/N = 4. The responses for dopamine to different concentrations were found to be linear between 0.25 and 50 muM with a correlation coefficient of 0.9974 and a sensitivity of 11. 76 pA/muM. The totally integrated CE-EC microchip should be able to fulfill the ideal of miniaturization and commercialization.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 43 条
[1]  
[Anonymous], ELECTROPHORESIS
[2]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[3]  
2-7
[4]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[5]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[6]   Palladium film decoupler for amperometric detection in electrophoresis chips [J].
Chen, DC ;
Hsu, FL ;
Zhan, DZ ;
Chen, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :758-762
[7]   Lowering the UV absorbance detection limit in capillary zone electrophoresis using a single linear photodiode array detector [J].
Culbertson, CT ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2629-2638
[8]   Prototyping of masks, masters, and stamps/molds for soft lithography using an office printer and photographic reduction [J].
Deng, T ;
Wu, HK ;
Brittain, ST ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3176-3180
[9]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[10]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457