Determination of biologically active low-molecular-mass thiols in human blood I. Fast qualitative and quantitative, gradient and isocratic reversed-phase high-performance liquid chromatography with photometric and fluorescence detection

被引:106
作者
Ivanov, AR
Nazimov, IV
Baratova, L
机构
[1] Russian Acad Sci, Shemyakin & Ovchinnikov Bioorgan Chem, Moscow 117871 V437, Russia
[2] MGU, Belozersky Inst Phys & Chem Inst, Moscow 119899, Russia
基金
美国国家卫生研究院;
关键词
thiols; homocysteine; aminothiols; monobromobimane; cysteine; glutathione; amino acids;
D O I
10.1016/S0021-9673(00)00713-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fast isocratic and gradient reversed-phase high-performance liquid chromatographic methods employing photometric and/or fluorescence detection are described for the precise reproducible simultaneous measurement of total homocysteine, cysteine, and glutathione in human blood. Sample preparation involves conversion of disulfides to free thiols with triphenylphosphine, precipitation of proteins with sulfosalicylic acid, and conjugation of thiols with monobromobimane. The aminothiol assay is optimized by reduction and derivatization step conditions (pH, temperature and time of reactions), as well as by chromatographic conditions to obtain reliable quantitative results within the concentration range corresponding to the levels of these thiols in human blood in norm and pathology. Its sensitivity allows the detection of aminothiol quantities >2 pmol. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 27 条
[1]  
ANDERSSON A, 1993, CLIN CHEM, V39, P1590
[2]   DETERMINATION OF FREE AND TOTAL HOMOCYSTEINE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
ARAKI, A ;
SAKO, Y .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 :43-52
[3]   HIGHER TOTAL PLASMA HOMOCYSTEINE IN VITAMIN-B12 DEFICIENCY THAN IN HETEROZYGOSITY FOR HOMOCYSTINURIA DUE TO CYSTATHIONINE BETA-SYNTHASE DEFICIENCY [J].
BRATTSTROM, L ;
ISRAELSSON, B ;
LINDGARDE, F ;
HULTBERG, B .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1988, 37 (02) :175-178
[4]   SENSITIVE MEASUREMENT OF GLUTATHIONE USING ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BURTON, NK ;
AHERNE, GW .
JOURNAL OF CHROMATOGRAPHY, 1986, 382 :253-257
[5]   Total homocysteine levels in plasma: high-performance liquid chromatographic determination with electrochemical detection and glassy carbon electrode [J].
D'Eramo, JL ;
Finkelstein, AE ;
Boccazzi, FO ;
Fridman, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 720 (1-2) :205-210
[6]  
Daskalakis I, 1996, BIOMED CHROMATOGR, V10, P205, DOI 10.1002/(SICI)1099-0801(199609)10:5<205::AID-BMC589>3.3.CO
[7]  
2-G
[8]  
FISKERSTRAND T, 1993, CLIN CHEM, V39, P263
[9]   Qualitative and quantitative determination of biologically active low-molecular-mass thiols in human blood by reversed-phase high-performance liquid chromatography with photometry and fluorescence detection [J].
Ivanov, AR ;
Nazimov, IV ;
Baratova, LA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :433-442
[10]   DETERMINATION OF PLASMA HOMOCYSTEINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
JACOBSEN, DW ;
GATAUTIS, VJ ;
GREEN, R .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (01) :208-214