Accurate Spectroscopic Calibration for Noninvasive Glucose Monitoring by Modeling the Physiological Glucose Dynamics

被引:54
作者
Barman, Ishan [1 ]
Kong, Chae-Ryon [1 ]
Singh, Gajendra P. [1 ]
Dasari, Ramachandra R. [1 ]
Feld, Michael S. [1 ]
机构
[1] MIT, George R Harrison Spect Lab, Cambridge, MA 02139 USA
关键词
BLOOD; FLUORESCENCE; SENSORS;
D O I
10.1021/ac100810e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The physiological lag between blood and interstitial fluid (ISF) glucose is a major challenge for noninvasive glucose concentration measurements. This is a particular problem for spectroscopic techniques, which predominantly probe ISF glucose, creating inconsistencies in calibration, where blood glucose measurements are used as a reference. To overcome this problem, we present a dynamic concentration correction (DCC) scheme, based on the mass transfer of glucose between blood and ISF, to ensure consistency with the spectral measurements. The proposed formalism allows the transformation of glucose in the concentration domain, ensuring consistency with the acquired spectra in the calibration model. Taking Raman spectroscopy as a specific example, we demonstrate that the predicted glucose concentrations using the DCC-based calibration model closely match the measured glucose concentrations, while those generated with the conventional calibration methods show significantly larger deviations from the measured values. In addition, we provide an analytical formula for a previously unidentified source of limiting uncertainty arising in spectroscopic glucose monitoring from a lack of knowledge of glucose kinetics in prediction samples. A study with human volunteers undergoing glucose tolerance tests indicates that this lag uncertainty, which is comparable in magnitude to the uncertainty arising from noise and nonorthogonality in the spectral data set, can be reduced substantially by employing the DCC scheme in spectroscopic calibration.
引用
收藏
页码:6104 / 6114
页数:11
相关论文
共 48 条
[1]   Quantitative Raman reaction monitoring using the solvent as internal standard [J].
Aarnoutse, PJ ;
Westerhuis, JA .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1228-1236
[2]   Standards of Medical Care in Diabetes-2009 [J].
不详 .
DIABETES CARE, 2009, 32 :S13-S61
[3]   Noninvasive glucose sensing [J].
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5429-5439
[4]   A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm [J].
Aussedat, B ;
Thome-Duret, V ;
Reach, G ;
Lemmonier, F ;
Klein, JC ;
Hu, Y ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) :1061-1071
[5]   Turbidity-Corrected Raman Spectroscopy for Blood Analyte Detection [J].
Barman, Ishan ;
Singh, Gajendra P. ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
ANALYTICAL CHEMISTRY, 2009, 81 (11) :4233-4240
[6]   An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[7]   Analytical method of estimating chemometric prediction error [J].
Berger, AJ ;
Feld, MS .
APPLIED SPECTROSCOPY, 1997, 51 (05) :725-732
[8]   MICRODIALYSIS MEASUREMENT OF THE ABSOLUTE GLUCOSE-CONCENTRATION IN SUBCUTANEOUS ADIPOSE-TISSUE ALLOWING GLUCOSE MONITORING IN DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
DIABETOLOGIA, 1992, 35 (12) :1177-1180
[9]   Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor [J].
Boyne, MS ;
Silver, DM ;
Kaplan, J ;
Saudek, CD .
DIABETES, 2003, 52 (11) :2790-2794
[10]  
Brereton R.G., 2007, Applied Chemometrics for Scientists