p24 antigen detection assay modified with a booster step for diagnosis and monitoring of human immunodeficiency virus type 1 infection

被引:75
作者
Sutthent, R
Gaudart, N
Chokpaibulkit, K
Tanliang, N
Kanoksinsombath, C
Chaisilwatana, P
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Pediat, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Obstet & Gynecol, Bangkok 10700, Thailand
[3] Mahidol Univ, Siriraj Hosp, Fac Med,Dept Microbiol, Natl HIV Repository & Bioinformat Ctr Thailand, Bangkok 10700, Thailand
关键词
D O I
10.1128/JCM.41.3.1016-1022.2003
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We modified a p24 antigen enzyme-linked immunosorbent assay as a method for diagnosis and monitoring of human immunodeficiency virus type 1 (HIV-1) subtype E infection. This modified assay is based on the use of preheated immune complex dissociation combined with a booster step using a regular Vironostika HIV-1 p24 antigen assay (bioMerieux) to decrease the lower limit of p24 antigen detection from 10 pg/ml (lower limit achievable when using a regular p24 antigen assay) to 0.5 pg/ml (100 virions/ml) by the new method. The correlation between the values obtained by the HIV-1 RNA (Amplicor HIV-1 Monitor) assay and the p24 antigen assay modified with a booster step antigen assay in 160 frozen plasma samples with known viral load and 80 blind fresh plasma samples by Spearman rank were 0.671 (R-2 = 0.450; P < 0.01) and 0.782 (R-2 = 0.612; P < 0.01). During antiretroviral treatment, the change of p24 antigen level at greater than or equal to0.5 log correlated well with the level of HIV-1 in plasma. In order to improve the early diagnosis of HIV-1 infection in 121 infants born to HIV-1-infected mothers, a heat-denatured plasma p24 antigen assay modified with a booster step was compared with DNA-PCR and HIV RNA (nucleic acid sequence-based amplification) assays. The sensitivity of the antigen test modified with a booster step was similar to that of the HIV-1 RNA (NASBA QL) assay and better than that of the DNA-PCR assay (100 versus 61.90%) for subjects 1 to 2 months old. The overall results from this study might renew interest in p24 antigen detection as an easily affordable alternative method for diagnosis of HIV-1 infection and monitoring of disease progression in developing countries.
引用
收藏
页码:1016 / 1022
页数:7
相关论文
共 25 条
[21]   Sensitivity and specificity of a qualitative RNA detection assay to diagnose HIV infection in young infants [J].
Simonds, RJ ;
Brown, TM ;
Thea, DM ;
Orloff, SL ;
Steketee, RW ;
Lee, FK ;
Palumbo, PE ;
Kalish, ML .
AIDS, 1998, 12 (12) :1545-1549
[22]   THE ANTIVIRAL EFFECT OF ZIDOVUDINE AND RIBAVIRIN IN CLINICAL-TRIALS AND THE USE OF P24 ANTIGEN LEVELS AS A VIROLOGIC MARKER [J].
SPECTOR, SA ;
KENNEDY, C ;
MCCUTCHAN, JA ;
BOZZETTE, SA ;
STRAUBE, RG ;
CONNOR, JD ;
RICHMAN, DD .
JOURNAL OF INFECTIOUS DISEASES, 1989, 159 (05) :822-828
[23]   Effect of perinatal short-course zidovudine on the clinical and virological manifestations of HIV-1 subtype E infection in infants [J].
Sutthent, R ;
Chokephaibulkit, K ;
Piyasujabul, D ;
Vanprapa, N ;
Roogpisuthipong, A ;
Chaisilwatana, P .
JOURNAL OF CLINICAL VIROLOGY, 2002, 25 (01) :47-56
[24]  
*UNAIDS WHO, 2001, AIDS EP UPD 2001 JOI
[25]  
Young NL, 2000, J ACQ IMMUN DEF SYND, V24, P401, DOI 10.1097/00126334-200008150-00001