Polychlorinated biphenyls (PCBs) detection in food samples using an electrochemical immunosensor

被引:35
作者
Laschi, S
Mascini, M
Scortichini, G
Fránek, M
Mascini, M
机构
[1] Univ Florence, Dipartimento Chim, I-50019 Florence, Italy
[2] Univ Teramo, Fac Agr, I-64100 Terano, TE, Italy
[3] Ist Zooprofilatt Abruzzo & Molise G Caporale, I-64100 Teramo, Italy
[4] Vet Res Inst, Dept Biotechnol, CS-62132 Brno, Czech Republic
关键词
immunosensor; screen-printed electrodes; polychlorinated biphenyls; competitive immunoassay; differential pulse voltammetry;
D O I
10.1021/jf0208637
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
In this work, a disposable electrochemical immunosensor, based on a competitive assay scheme, was applied to detect polychlorinated biphenyls (PCBs) in food. For this purpose, antibodies against PCBs were directly immobilized onto the carbon surface of a disposable screen-printed electrode. A competition between the PCBs present in the sample and a fixed concentration of an enzyme-labeled PCB was realized and evaluated by electrochemical detection. Alkaline phosphatase was used as the enzyme label, coupled with differential pulse voltammetry (DPV) as the electrochemical technique. The immunosensor was tested on aroclor mixture detection (1242 and 1248) and then on some typologies of food samples to evaluate the possible application for real sample analysis. Samples analyzed were from different matrixes, such as sheep milk, bovine adipose tissue, and bovine muscle. Results obtained were compared with the accredited results according to ISO 17025 methods for PCB detection (HRGC-LRMS) as a confirmatory analysis. Preliminary results show the possibility to use this device as a screening method in food sample analysis. The negligible matrix effect observed may lead to a simplified extraction procedure, and considerable time and consumable savings are the immediate benefits given by the proposed method.
引用
收藏
页码:1816 / 1822
页数:7
相关论文
共 28 条
[1]   MASS-PRODUCTION OF BIOSENSORS [J].
ALVAREZICAZA, M ;
BILITEWSKI, U .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :A525-A533
[2]   Direct electrochemical immunosensor for polychlorinated biphenyls [J].
Bender, S ;
Sadik, OA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (06) :788-797
[3]   Food contamination by PCBs and dioxins [J].
Bernard, A ;
Hermans, C ;
Broeckaert, F ;
De Poorter, G ;
De Cock, A ;
Houins, G .
NATURE, 1999, 401 (6750) :231-232
[4]   DEVELOPMENT OF A FLOW-INJECTION ANALYSIS (FIA) IMMUNOSENSOR FOR THE DETECTION OF ESCHERICHIA-COLI [J].
BOUVRETTE, P ;
LUONG, JHT .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 27 (2-3) :129-137
[5]   SYNTHESIS OF A FLUORESCENT ANALOG OF POLYCHLORINATED-BIPHENYLS FOR USE IN A CONTINUOUS-FLOW IMMUNOSENSOR ASSAY [J].
CHARLES, PT ;
CONRAD, DW ;
JACOBS, MS ;
BART, JC ;
KUSTERBECK, AW .
BIOCONJUGATE CHEMISTRY, 1995, 6 (06) :691-694
[6]  
Del Carlo W, 1999, FIELD ANAL CHEM TECH, V3, P179, DOI 10.1002/(SICI)1520-6521(1999)3:3<179::AID-FACT5>3.0.CO
[7]  
2-G
[8]   Flexible amperometric transducers for biosensors based on a screen printed three electrode system [J].
Erlenkötter, A ;
Kottbus, M ;
Chemnitius, GC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 481 (01) :82-94
[9]   Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography high resolution mass spectrometry (HRGC/HRMS) analytical procedures [J].
Ferrario, J ;
Byrne, C ;
Dupuy, AE .
CHEMOSPHERE, 1997, 34 (11) :2451-2465
[10]   Levels and congener distributions of PCDDs, PCDFs and non-ortho PCBs in Belgian foodstuffs -: Assessment of dietary intake [J].
Focant, JF ;
Eppe, G ;
Pirard, C ;
Massart, AC ;
André, JE ;
De Pauw, E .
CHEMOSPHERE, 2002, 48 (02) :167-179