A Monte Carlo study of IMRT beamlets in inhomogeneous media

被引:43
作者
Jones, AO [1 ]
Das, IJ
Jones, FL
机构
[1] Drexel Univ, Coll Med, Philadelphia, PA 19102 USA
[2] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[3] Geisinger Med Ctr, Dept Thorac Med, Danville, PA USA
关键词
inhomogeneity corrections; Monte Carlo calculations;
D O I
10.1118/1.1539040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity Modulated Radiation Therapy (IMRT) has trended toward smaller multiple radiation fields thereby increasing the resolution of the intensity map. Vendors have introduced multileaf collimators with beam apertures of 0.5 cm and less. The beam characteristics of these smaller fields have not been adequately assessed, especially in the presence of inhomogeneities. Most dosimetric devices have significant limitations due to finite size, dose rate, and energy dependence. We studied the effect of inhomogeneities on small beamlets. The 6, 15, and 24 MV beams were modeled using the EGSnrc Monte Carlo code. Point source beams of circular field sizes 0.5, 1.0, 3.0, 5.0, and 10 cm were simulated in a water phantom at 100 SSD. A 3 cm inhomogeneity of lung tissue was incorporated between 3 and 6 cm in the phantom. The depth dose curves and profiles were compared by beam size and density of the inhomogeneity. The Monte Carlo simulations show that for small fields a marked dose decrease in the presence of low-density media due to the lack of lateral electronic equilibrium is observed. As the density and field size increase, the dose reduction is less pronounced and for the 10 cm field there is an increased dose as expected due to lack of attenuation. This data suggests that current TPS may dramatically over- or underestimate the dose in inhomogeneous media for small field sizes that are used for IMRT. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 17 条
[1]   The impact of electron transport on the accuracy of computed dose [J].
Arnfield, MR ;
Siantar, CH ;
Siebers, J ;
Garmon, P ;
Cox, L ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (06) :1266-1274
[2]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[3]  
BJAMGARD BE, 1990, MED PHYS, V17, P794
[4]  
Kawrakow I, PIRS701 NRCC
[5]   Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nusslin, F .
MEDICAL PHYSICS, 1997, 24 (04) :535-536
[6]   The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy [J].
Martens, C ;
De Wagter, C ;
De Neve, W .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2519-2530
[7]   ENERGY AND ANGULAR-DISTRIBUTIONS OF PHOTONS FROM MEDICAL LINEAR ACCELERATORS [J].
MOHAN, R ;
CHUI, C ;
LIDOFSKY, L .
MEDICAL PHYSICS, 1985, 12 (05) :592-597
[8]   MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS [J].
RICE, RK ;
HANSEN, JL ;
SVENSSON, GK ;
SIDDON, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1087-1099
[9]  
Rogers D.W.O., PIRS702 NRCC
[10]   Dosimetric characterization of radiosurgical beams with a diamond detector [J].
Rustgi, SN ;
Frye, DMD .
MEDICAL PHYSICS, 1995, 22 (12) :2117-2121