The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy

被引:134
作者
Martens, C [1 ]
De Wagter, C [1 ]
De Neve, W [1 ]
机构
[1] State Univ Ghent Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1088/0031-9155/45/9/306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Volume averaging and lack of electronic equilibrium complicate accurate dosimetry of small photon fields. In this paper the performance of the PinPoint ion chamber for characterizing small fields used in intensity-modulated radiotherapy (IMRT) was investigated and the results were compared with those obtained using the Markus ion chamber and a diamond detector. Sharp beam penumbras were measured for a 5 x 5 cm field defined using a cerrobend block mounted on the accelerator head. In addition, output factors were measured for a 6 MV photon beam and a variety of small rectangular fields collimated widthwise using the multileaf collimator (MLC) in combination with the back-up jaws. From this study, a reference field of 5 x 5 cm and a measuring depth of 5 cm are recommended. This is related to the over-response of the PinPoint chamber to low-energy Compton scattered photons, an effect that was investigated rigorously and turned out to limit the scope of this ionization chamber. However, taking into account some limitations, the PinPoint chamber is an excellent detector for output measurements in small fields down to 2 cm. In profile measurements the chamber causes a broadening of the measured penumbras but its spatial resolution is superior to that of the Markus chamber.
引用
收藏
页码:2519 / 2530
页数:12
相关论文
共 15 条
[1]  
BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475
[2]   A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering [J].
Burch, SE ;
Kearfott, KJ ;
Trueblood, JH ;
Sheils, WC ;
Yeo, JI ;
Wang, CKC .
MEDICAL PHYSICS, 1997, 24 (05) :775-783
[3]   Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams [J].
De Vlamynck, K ;
Palmans, H ;
Verhaegen, F ;
De Wagter, C ;
De Neve, W ;
Thierens, H .
MEDICAL PHYSICS, 1999, 26 (09) :1874-1882
[4]  
DUTREIX A, 1997, MONITOR UNIT CALCULA, P27
[5]   Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams [J].
Francescon, P ;
Cora, S ;
Cavedon, C ;
Scalchi, P ;
Reccanello, S ;
Colombo, F .
MEDICAL PHYSICS, 1998, 25 (04) :503-511
[6]   EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM [J].
GALVIN, JM ;
SMITH, AR ;
MOELLER, RD ;
GOODMAN, RL ;
POWLIS, WD ;
RUBENSTEIN, J ;
SOLIN, LJ ;
MICHAEL, B ;
NEEDHAM, M ;
HUNTZINGER, CJ ;
KLIGERMAN, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04) :789-801
[7]   A comparison of dosimetry techniques in stereotactic radiosurgery [J].
Heydarian, M ;
Hoban, PW ;
Beddoe, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :93-110
[8]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229
[9]   Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nusslin, F .
MEDICAL PHYSICS, 1997, 24 (04) :535-536
[10]   Activity, friendships and wellbeing in residential settings for older people [J].
McKee, KJ ;
Harrison, G ;
Lee, K .
AGING & MENTAL HEALTH, 1999, 3 (02) :143-152