RAB-plate vs Richards CHS plate for unstable trochanteric hip fractures - A randomized study of 233 patients with 1-year follow-up

被引:29
作者
Buciuto, R [1 ]
Uhlin, B [1 ]
Hammerby, S [1 ]
Hammer, R [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthopaed Surg, N-7006 Trondheim, Norway
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1998年 / 69卷 / 01期
关键词
D O I
10.3109/17453679809002350
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We prospectively randomized 233 patients with unstable trochanteric hip fractures for treatment with a 120 degrees fixed angle blade-plate having a buttress rod (group A, n 111) or a 135 degrees compression hip screw (group B, n 122). The minimum follow-up time was 1 year. The ratio of technical failure was 9% in group A and 19% in group B (p = 0.06). 79 (87%) fractures in group A and 65 (68%) fractures in group B healed without any complication (p = 0.003). Malunion occurred in 2 cases in group A and in 15 cases in group a (p = 0.002).
引用
收藏
页码:25 / 28
页数:4
相关论文
共 24 条
[1]
COMPLICATIONS AFTER TROCHANTERIC FRACTURES - A COMPARISON BETWEEN ENDER AND NAIL-PLATE OSTEOSYNTHESIS [J].
ANDERSSON, S ;
HERRLIN, K ;
WALLOE, A ;
LIDGREN, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (02) :187-191
[2]
APEL DM, 1989, CLIN ORTHOP RELAT R, P156
[3]
GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[4]
FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[5]
CHANG WS, 1987, CLIN ORTHOP RELAT R, P141
[6]
INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[7]
TREATMENT OF THE UNSTABLE INTERTROCHANTERIC FRACTURE - EFFECT OF THE PLACEMENT OF THE SCREW, ITS ANGLE OF INSERTION, AND OSTEOTOMY [J].
DENHARTOG, BD ;
BARTAL, E ;
COOKE, F .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (05) :726-733
[8]
DOPPELT SH, 1980, ORTHOP CLIN N AM, V11, P507
[9]
THE STABILITY OF INTERTROCHANTERIC FRACTURES TREATED WITH A SLIDING SCREW-PLATE [J].
FLORES, LA ;
HARRINGTON, IJ ;
HELLER, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :37-40
[10]
THE PUGH NAIL-PLATE - A LOW INCIDENCE OF DEVICE FAILURE [J].
GIBSON, JNA ;
ESPLEY, AJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1987, 18 (01) :24-27