Evaluation of a dual chamber implantable cardioverter defibrillator for the treatment of atrial and ventricular arrhythmias

被引:12
作者
Boriani, G
Wollmann, C
Biffi, M
Kühl, M
Schuchert, A
Sperzel, J
Stiller, S
Gasparini, G
Böcker, D
机构
[1] Univ Bologna, Inst Cardiol, Policlin S Orsola, I-40138 Bologna, Italy
[2] Univ Munster, Dept Cardiol, D-4400 Munster, Germany
[3] Guidant Inc, St Paul, MN USA
[4] Univ Hamburg, Hamburg, Germany
[5] Univ Ulm, D-89069 Ulm, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
atrial tachyarrhythmia; atrialftbrillation; implantable cardioverter defibrillator; detection time; cardioversion; defibrillation;
D O I
10.1046/j.1460-9592.2003.00072.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eighty-nine patients with a documented history of atrial tachyarrhythmias or fibrillation (AF) received a cardioverter defibrillator designed to selectively differentiate and treat atrial and ventricular arrhythmias. Twenty-two patients received a coronary sinus lead and, therefore, could use a separate shock vector for selective treatment of atrial tachyarrhythmias/AE The device is designed to treat tachyarrhythmias with antitachycardia pacing (ATP) and/or shock therapy using an atrial and/or a ventricular shock vector. Patients underwent induction and shock termination of atrial or dual tachyarrhythmias (AF/VF) to verify proper device function and to measure the arrhythmia detection time with enhancements and preventive algorithms programmed On and Off, respectively. Detection time for 329 VF inductions was 2.41 +/- 0.64 seconds with enhancements On and 2.29 +/- 0.47 with enhancements Off (NS). At implant or predischarge, 283 AF and/or AF/VF (121 atrial and 162 atrial/ventricular fibrillation) were induced. Shock conversion efficacy was 89.8% with AF conversion energies ranging from 0.9 to 27 J. Thirteen of the 23 patients had atrial shock conversions using the separate shock vector with an average conversion energy of 1.9 +/- 1.41. (range 0.5-5 J) A During follow-up the efficacy of ATP on atrial tachyarrhythmias was 59% and the efficacy of delivered shocks on AF was 85%. This new dual chamber cardioverter defibrillator appropriately detected and classified atrial arrhythmias, and shock therapy for AF was highly effective. The detection algorithm differentiated atrial tachyarrhythmia/AF and did not delay VF detection. The separate shock vector converted induced AF with energies ranging from 0.6 to 5 J.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 11 条
[1]   Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator [J].
Adler, SW ;
Wolpert, C ;
Warman, EN ;
Musley, SK ;
Koehler, JL ;
Euler, DE .
CIRCULATION, 2001, 104 (08) :887-892
[2]   Atrial defibrillation thresholds of electrode configurations available to an atrioventricular defibrillator [J].
Benser, ME ;
Walcott, GP ;
Killingsworth, CR ;
Girouard, SD ;
Morris, MM ;
Ideker, RE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) :957-964
[3]   Current clinical perspectives on implantable devices for atrial defibrillation [J].
Boriani, G ;
Biffi, M ;
Martignani, C ;
Luceri, R ;
Bartolini, P ;
Branzi, A .
CURRENT OPINION IN CARDIOLOGY, 2002, 17 (01) :82-89
[4]   Effects of consistent atrial pacing and atrial rate stabilization - two pacing algorithms to suppress recurrent paroxysmal atrial fibrillation in brady-tachy syndrome [J].
Boriani, G ;
Biffi, M ;
Padeletti, L ;
Spampinato, A ;
Botto, GL ;
Pignalberi, C ;
Grammatico, A ;
Hettrick, DA ;
De Seta, F ;
Branzi, A .
EUROPEAN HEART JOURNAL SUPPLEMENTS, 2001, 3 (0P) :P7-P15
[5]   Atrial defibrillation with a transvenous lead - A randomized comparison of active can shocking pathways [J].
Cooklin, M ;
Olsovsky, MR ;
Brockman, RG ;
Shorofsky, SR ;
Gold, MR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) :358-362
[6]   Antitachycardia pacing therapies to terminate atrial tachyarrhythmias: the AT500 Italian Registry [J].
Disertori, M ;
Padeletti, L ;
Santini, M ;
Dini, P ;
Gasparini, M ;
Inama, G ;
Botto, M ;
Boriani, G ;
Capucci, A ;
Ricci, R ;
Gramegna, L ;
Del Greco, M ;
Grammatico, A ;
Vimercati, M .
EUROPEAN HEART JOURNAL SUPPLEMENTS, 2001, 3 (0P) :P16-P24
[7]   Clinical experience with a dual-chamber implantable cardioverter defibrillator to treat atrial tachyarrhythmias [J].
Gold, MR ;
Sulke, N ;
Schwartzman, DS ;
Mehra, R ;
Euler, DE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (11) :1247-1253
[8]   Association between atrial fibrillation and appropriate implantable cardioverter defibrillator therapy:: Results from a prospective study [J].
Grönefeld, GC ;
Mauss, O ;
Li, YG ;
Klingenheben, T ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (11) :1208-1214
[9]   Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation:: Insights from a study using a new implantable device [J].
Israel, CW ;
Ehrlich, JR ;
Grönefeld, G ;
Klesius, A ;
Lawo, T ;
Lemke, B ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) :355-363
[10]   Clinical experience with implantable atrial and combined atrioventricular defibrillators [J].
Jung, W ;
Wolpert, C ;
Esmailzadeh, B ;
Spehl, S ;
Herwig, S ;
Schumacher, B ;
Lewalter, T ;
Omran, H ;
Schimpf, R ;
Vahlhaus, C ;
Welz, A ;
Lüderitz, B .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (Suppl 1) :185-195