X-ray detector calibration at CEA/Bruyeres-le-Chatel

被引:11
作者
Beck, L
Stemmler, P
Ban, G
Villette, B
Frotte, V
Bizeuil, C
Boutin, JY
Nazet, C
机构
[1] Commsrt. à l'Energie Atomique, Service CEM/MR, 91680 Bruyeres-le-Chatel
关键词
D O I
10.1016/S0168-9002(96)80018-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At CEA/Bruyeres-le-Chatel (Service GEM), then are facilities to calibrate X-ray detectors from 200 eV to 100 keV, with an accuracy of 4% at high energies (E > 3 keV). The source is the direct radiation from the X-ray tubes [C-K alpha (277 eV) to Ti-K alpha K beta (4.51/4.93 keV)] or fluorescence emission from secondary targets [ME(K alpha) (1.25 keV) to U-K alpha (98 keV)]. In addition, calibrations are carried out with the synchrotron radiation of the Super-AGO storage ring (LURE-Orsay), by selecting the monoenergetic beams with a double crystal monochromator which is tunable between 0.8 and 8 keV. The resolution is better than 1 eV. This last tool is very useful in the study of the absorption edges of the detector compounds (for example, Si K-edge and Ar K-edge). Some examples are presented of results obtained between 1 and 50 keV, with special reference to high flux detectors such as gold photocathodes and silicon avalanche photodiodes. Thick silicon photodiodes (for the high energy range) were also calibrated.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 24 条
[11]   HIGH TIME RESOLUTION X-RAY MEASUREMENTS WITH AN AVALANCHE PHOTODIODE DETECTOR [J].
KISHIMOTO, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :824-827
[12]  
KROTH U, 1900, APPL OPTICS, V2918, P2659
[13]   FIRST EXPERIMENTAL RESULTS ON NEW MICROSTRIP 3-DIMENSIONAL GEOMETRY [J].
LEMONNIER, M ;
BAHRI, A ;
BORDESSOULE, M ;
BARTOL, F ;
LABEQUE, A ;
LIU, Z ;
MEGTERT, S ;
ROULLIAY, M ;
RAVET, MF ;
ROUSSEAUX, F ;
PERROCHEAU, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01) :274-276
[14]  
LEPY MC, 1996, IN PRESS NOTE TECHNI
[15]  
MIRONE A, 1993, IN PRESS P XRAY MICR, V4
[16]   MEASUREMENT OF THE SPECTRAL EFFICIENCY OF ENERGY DISPERSIVE SI(LI) DETECTORS BELOW 5 KEV PHOTON ENERGY USING BESSY AS A STANDARD SOURCE [J].
MULLER, P ;
RIEHLE, F ;
TEGELER, E ;
WENDE, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :569-571
[17]   THE USE OF AVALANCHE PHOTODIODES FOR THE DETECTION OF SOFT X-RAYS [J].
PALMER, JR ;
MORRISON, GR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :828-831
[18]   ULTRA-HIGH PRESSURE PROPORTIONAL-COUNTERS .2. XENON [J].
SOOD, RK ;
YE, Z ;
MANCHANDA, RK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02) :384-393
[19]   PHOTODIODES AS DETECTORS WITH HIGH DYNAMIC-RANGE FOR X-RAY REFLECTIVITY MEASUREMENTS [J].
STORB, C ;
DEDEK, U ;
WEBER, W ;
LENGELER, B ;
SCHUSTER, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (03) :544-548
[20]  
SUSINI J, 1988, CR ACAD SCI II, V306, P1157