LC-MS/MS coupled with immunoaffinity extraction for determination of estrone, 17β-estradiol and estrone 3-sulfate in human plasma

被引:33
作者
Hosogi, Jun [1 ]
Tanaka, Hideyuki [1 ]
Fujita, Kazuhiro [1 ]
Kuwabara, Takashi [1 ]
Ikegawa, Shigeo [2 ]
Kobayashi, Norihiro [3 ]
Mano, Nariyasu [4 ,5 ]
Goto, Junichi [4 ]
机构
[1] Kyowa Hakko Kirin Co Ltd, Div Res, Pharmacokinet Res Labs, Nagaizumi, Shizuoka 4118731, Japan
[2] Kinki Univ, Fac Pharmaceut Sci, Osaka 5778502, Japan
[3] Kobe Pharmaceut Univ, Higashinada Ku, Kobe, Hyogo 6588558, Japan
[4] Tohoku Univ Hosp, Dept Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808574, Japan
[5] Tohoku Univ, Grad Sch Pharmaceut Sci, Lab Clin Pharm, Aoba Ku, Sendai, Miyagi 9808574, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 02期
关键词
Estradiol; Estrone; Estrone sulfate; LC-MS/MS; Immunoaffinity extraction; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; BREAST-CANCER; HUMAN SERUM; RIA METHOD; ESTRADIOL; SULFATE; THERAPY; ASSAY;
D O I
10.1016/j.jchromb.2009.08.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of estrogens in plasma is important in evaluation of effects of some anticancer drugs, such as aromatase inhibitors. However, as reported previously, high performance liquid chromatography-radio Immunoassay (HPLC-RIA) and liquid chromatography-tandem mass spectrometry (I.C-MS/MS) with chemical derivatization require complicated sample preparation In this study, a highly sensitive and simple method for determination of estrone (E1), 17 beta-estradiol (E2) and estrone 3-sulfate (EIS) in human plasma has been developed. Following diethylether extraction from plasma. analytes were purified by immunosorbents and then determined by LC-MS/MS using electrospray ionization (ESI). Immunosorbents were prepared by immobilization of specific antibodies raised against each analyte onto solid support Use of selective immunosorbents in sample preparation removed interference in plasma samples that would cause ionization suppression, and markedly improved the sensitivity of LC-MS/MS for these analytes, without derivatization. Calibration curves of each analyte showed good linearity and reproducibility over the range of 005-50 pg/injection for E1.0.2-50 pg/injection for E2 and 0.05-300 pg/injection for E1 S. respectively. The mean values of lower limits of quantification (LLOQ) in human plasma corrected by recovery of deuterated estrogens (internal standard, I S.) were 0.1892 pg/mL for E7, 0.7064 pg/mL for E2 and 0.3333 pg/mL for E1 S. respectively. These LLOQ values were comparable to those previous reported using HPLC-RIA and LC-MS/MS. Using this method, the normal levels of three estrogens in healthy female plasma (n=5) were determined. The mean values of E1, E2 and El S were 38.0 pg/mL (range 24.8-53.0).34.3 pg/ml. (22 6-46.6) anti 786 pg/mL. (163-2080), respectively The immunoaffinity LC-MS/MS described here allows sensitive and accurate quantification of E1, E2 and E1 S without laborious sample preparation (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:222 / 227
页数:6
相关论文
共 20 条
[1]   Five years of letrozole compared with tamoxifen as initial adjuvant therapy for postmenopausal women with endocrine-responsive early breast cancer:: Update of study BIG 1-98 [J].
Coates, Alan S. ;
Keshaviah, Aparna ;
Thuerlimann, Beat ;
Mouridsen, Henning ;
Mauriac, Louis ;
Forbes, John F. ;
Paridaens, Robert ;
Castiglione-Gertsch, Monica ;
Gelber, Richard D. ;
Colleoni, Marco ;
Lang, Istvan ;
Del Mastro, Lucia ;
Smith, Ian ;
Chirgwin, Jacquie ;
Nogaret, Jean-Marie ;
Pienkowski, Tadeusz ;
Wardley, Andrew ;
Jakobsen, Erik H. ;
Price, Karen N. ;
Goldhirsch, Aron .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (05) :486-492
[2]   A randomized trial of exemestane after two to three years of tamoxifen therapy in postmenopausal women with primary breast cancer [J].
Coombes, RC ;
Hall, E ;
Gibson, LJ ;
Paridaens, R ;
Jassem, J ;
Delozier, T ;
Jones, SE ;
Alvarez, I ;
Bertelli, G ;
Ortmann, O ;
Coates, AS ;
Bajetta, E ;
Dodwell, D ;
Coleman, RE ;
Fallowfield, LJ ;
Mickiewicz, E ;
Andersen, J ;
Lonning, PE ;
Cocconi, G ;
Stewart, A ;
Stuart, N ;
Snowdon, CF ;
Carpentieri, M ;
Massimini, G ;
Bliss, JM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (11) :1081-1092
[3]  
Dorgan JF, 2002, JNCI-J NATL CANCER I, V94, P606
[4]   Quantification of 17β-estradiol residues in bovine serum by liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization [J].
Draisci, R ;
Palleschi, L ;
Ferretti, E ;
Marchiafava, C ;
Lucentini, L ;
Cammarata, P .
ANALYST, 1998, 123 (12) :2605-2609
[5]   A novel HPLC-RIA method for the simultaneous detection of estrone, estradiol and estrone sulphate levels in breast cancer tissue [J].
Geisler, J ;
Berntsen, H ;
Lonning, PE .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2000, 72 (05) :259-264
[6]   Plasma sex steroid hormone levels and risk of breast cancer in postmenopausal women [J].
Hankinson, SE ;
Willett, WC ;
Manson, JE ;
Colditz, GA ;
Hunter, DJ ;
Spiegelman, D ;
Barbieri, RL ;
Speizer, FE .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1998, 90 (17) :1292-1299
[7]   Estrogen receptor status by immunohistochemistry is superior to the ligand-binding assay for predicting response to adjuvant endocrine therapy in breast cancer [J].
Harvey, JM ;
Clark, GM ;
Osborne, CK ;
Allred, DC .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (05) :1474-1481
[8]   Results of the ATAC (Arimidex, Tamoxifen, Alone or in Combination) trial after completion of 5 years' adjuvant treatment for breast cancer [J].
Howell, A ;
Cuzick, J ;
Baum, M ;
Buzdar, A ;
Dowsett, M ;
Forbes, JF ;
Hoctin-Boes, G ;
Houghton, I ;
Locker, GY ;
Tobias, JS .
LANCET, 2005, 365 (9453) :60-62
[9]   Enantioselective immunoaffinity extraction for simultaneous determination of optically active bufuralol and its metabolites in human plasma by HPLC [J].
Ikegawa, S ;
Matsuura, K ;
Sato, T ;
Isriyanthi, NMR ;
Niwa, T ;
Miyairi, S ;
Takashina, H ;
Kawashima, Y ;
Goto, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (01) :1-9
[10]   Analysis of steroid hormones in effluents of wastewater treatment plants by liquid chromatography-tandem mass spectrometry [J].
Ingrand, V ;
Herry, G ;
Beausse, J ;
de Roubin, MR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) :99-104