Evaluation of basic algorithms for transferring quantitative multivariate calibrations between scanning grating and FT NIR spectrometers

被引:32
作者
Leion, H [1 ]
Folestad, S [1 ]
Josefson, M [1 ]
Sparén, A [1 ]
机构
[1] AstraZeneca R&D, Analyt Dev, Pharmaceut & R&D, SE-43183 Molndal, Sweden
关键词
near infrared spectroscopy; diffuse-reflectance; calibration transfer; multivariate quantitative calibrations; partial least squares regression; solid pharmaceutical formulations;
D O I
10.1016/j.jpba.2004.09.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A key issue in near infrared spectroscopy (NIR) is the possibility to use calibrations generated on one instrument for predictions on others. A number of methods for calibration transfer have been proposed, but which method to choose is typically not straightforward. An evaluation of a number of methods for transferring quantitative calibrations between different instruments was carried out on near infrared diffuse-reflectance data from a pharmaceutical formulation. Six instruments were included in the study, five of which were scanning grating instruments, both with and without fibre-optic probe configuration, and one of which was a Fourier-transform instrument, equipped with a fibre-optic probe. The results show that it is possible to transfer calibrations between different instruments, provided that a structured procedure is used. Simple techniques for calibration transfer, such as slope/bias correction on the predicted results, as well as standard normal variate transformation and local centring of the raw spectra, gave considerably lower prediction errors on transfer than did standardisation with a certified diffuse-reflectance standard, or direct transfer without any transfer function. Notably, including more than one instrument in the calibration also improved the prediction ability of the models on calibration transfer. No significant differences in wavelength scale were found when a certified diffuse-reflectance wavelength standard was measured on the instruments studied. Nor did simulated wavelength scale differences below +/-0.3 nm cause any significant change in the prediction errors. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 52 条
  • [41] SHENK JS, 1996, 7 INT C NEAR INFR SP, P112
  • [42] An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra
    Sjöblom, J
    Svensson, O
    Josefson, M
    Kullberg, H
    Wold, S
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 44 (1-2) : 229 - 244
  • [43] Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets
    Sparén, A
    Malm, M
    Josefson, M
    Folestad, S
    Johansson, J
    [J]. APPLIED SPECTROSCOPY, 2002, 56 (05) : 586 - 592
  • [44] STRANG G, 1994, AM SCI, V82, P250
  • [45] Classification of chemically modified celluloses using a near-infrared spectrometer and soft independent modeling of class analogies
    Svensson, O
    Josefson, M
    Langkilde, FW
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (12) : 1826 - 1835
  • [46] Improvement of PLS model transferability by robust wavelength selection
    Swierenga, H
    de Groot, PJ
    de Weijer, AP
    Derksen, MWJ
    Buydens, LMC
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 41 (02) : 237 - 248
  • [47] A rapid quantitative assay of intact paracetamol tablets by reflectance near-infrared spectroscopy
    Trafford, AD
    Jee, RD
    Moffat, AC
    Graham, P
    [J]. ANALYST, 1999, 124 (02) : 163 - 167
  • [48] PLS regression on wavelet compressed NIR spectra
    Trygg, J
    Wold, S
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 42 (1-2) : 209 - 220
  • [49] Wavelets - something for analytical chemistry?
    Walczak, B
    Massart, DL
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (08) : 451 - 463
  • [50] MULTIVARIATE INSTRUMENT STANDARDIZATION
    WANG, YD
    VELTKAMP, DJ
    KOWALSKI, BR
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (23) : 2750 - 2756