Therapeutic drug monitoring of flecainide in serum using high-performance liquid chromatography and electrospray mass spectrometry

被引:13
作者
Breindahl, T [1 ]
机构
[1] Hjorring Bronderslev Hosp, Dept Clin Chem, DK-9800 Hjorring, Denmark
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 746卷 / 02期
关键词
flecainide;
D O I
10.1016/S0378-4347(00)00343-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-performance liquid chromatography with electrospray mass spectrometry (LC-MS) was used for analysis of the drug flecainide in serum. The clean-up was performed by solid-phase extraction, and an aromatic ring positional isomer was used as internal standard. Results from method validation on spiked serum samples showed excellent reproducibility; intra- and inter-assay variations (C.V.% and %Bias) were less than 6% within the therapeutic concentration range of the drug (0.2-1.0 mu g/ml). Linearity was demonstrated from 0.05 to 2.0 mu g/ml. The limit of detection and quantification was 0.025 and 0.05 mu g/ml, respectively. Due to the high selectivity of the mass spectrometric detection: no interferences were observed. Results from clinical samples (n=18) from patients in treatment with Tambocor (flecainide acetate) showed excellent correlation with parallel data obtained from a method based on high-performance liquid chromatography (HPLC) with fluorescence detection after liquid/liquid extraction. The chromatographic separation of flecainide and internal standard was improved compared to earlier HPLC methods. The methodology is simple, accurate and requires only 0.25 ml of sample. It is a well suited method for routine therapeutic drug monitoring in a hospital or clinical chemistry laboratory. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 24 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE ENANTIOMERS OF FLECAINIDE IN HUMAN PLASMA AND URINE [J].
ALESSISEVERINI, S ;
JAMALI, F ;
PASUTTO, FM ;
COUTTS, RT ;
GULAMHUSEIN, S .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1990, 79 (03) :257-260
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE MEASUREMENT OF MEXILETINE AND FLECAINIDE IN BLOOD-PLASMA OR SERUM [J].
BHAMRA, RK ;
FLANAGAN, RJ ;
HOLT, DW .
JOURNAL OF CHROMATOGRAPHY, 1984, 307 (02) :439-444
[3]   A RAPID LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF FLECAINIDE IN HUMAN-BLOOD PLASMA USING ULTRAVIOLET DETECTION [J].
BOUTAGY, J ;
RUMBLE, FM ;
SHENFIELD, GM .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (13) :2579-2590
[4]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF FLECAINIDE IN PLASMA [J].
BROLY, F ;
MARECAUX, P ;
HOUDRET, N ;
LHERMITTE, M ;
HOUSSIN, R .
BIOMEDICAL CHROMATOGRAPHY, 1991, 5 (06) :248-250
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF FLECAINIDE, A NEW ANTI-ARRHYTHMIC, IN HUMAN-PLASMA AND URINE [J].
CHANG, SF ;
WELSCHER, TM ;
MILLER, AM ;
OBER, RE .
JOURNAL OF CHROMATOGRAPHY, 1983, 272 (02) :341-350
[6]   APPLICATION OF A BONDED-PHASE EXTRACTION COLUMN FOR RAPID SAMPLE PREPARATION OF FLECAINIDE FROM HUMAN-PLASMA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS - FLUORESCENCE OR ULTRAVIOLET DETECTION [J].
CHANG, SF ;
MILLER, AM ;
FOX, JM ;
WELSCHER, TM .
THERAPEUTIC DRUG MONITORING, 1984, 6 (01) :105-111
[7]  
CONRAD GJ, 1984, AM J CARDIOL, V53, pB41
[8]   DEVELOPMENT OF FLUOROIMMUNOASSAYS FOR FLECAINIDE [J].
COXON, RE ;
HODGKINSON, AJ ;
SIDKI, AM ;
LANDON, J ;
GALLACHER, G .
THERAPEUTIC DRUG MONITORING, 1987, 9 (04) :478-483
[9]   FLUOROMETRIC LIQUID-CHROMATOGRAPHIC ASSAY OF THE ANTIARRHYTHMIC AGENT FLECAINIDE IN BLOOD-PLASMA [J].
DEJONG, JW ;
HEGGE, JAJ ;
HARMSEN, E ;
DETOMBE, PP .
JOURNAL OF CHROMATOGRAPHY, 1982, 229 (02) :498-502