The role of collagen cross-links in biomechanical behavior of human aortic heart valve leaflets - Relevance for tissue engineering

被引:151
作者
Balguid, Angelique
Rubbens, Mirjam P.
Mol, Anita
Bank, Ruud A.
Bogers, Ad J. J. C.
Van Kats, Jorge P.
De Mol, Bas A. J. M.
Baaijens, Frank P. T.
Bouten, Carlijn V. C.
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] Eindhoven Univ Technol, Dutch Polymer Inst, NL-5600 MB Eindhoven, Netherlands
[3] TNO Prevent & Hlth, Gaubius Lab, Leiden, Netherlands
[4] Erasmus Univ, Med Ctr, Rotterdam Heart Valve Bank, Rotterdam, Netherlands
[5] Erasmus Univ, Med Ctr, Dept Cardiothorac Surg, Rotterdam, Netherlands
[6] Univ Amsterdam, Acad Med Ctr, Dept Cardiopulm Surg, NL-1105 AZ Amsterdam, Netherlands
来源
TISSUE ENGINEERING | 2007年 / 13卷 / 07期
关键词
MECHANICAL-PROPERTIES; EXTRACELLULAR-MATRIX; AGE; PYRIDINOLINE; PYRIDINIUM; ELASTIN; STRETCH; ADULT;
D O I
10.1089/ten.2006.0279
中图分类号
Q813 [细胞工程];
学科分类号
摘要
A major challenge in tissue engineering of functional heart valves is to determine and mimic the dominant tissue structures that regulate heart valve function and in vivo survival. In native heart valves, the anisotropic matrix architecture assures sustained and adequate functioning under high-pressure conditions. Collagen, being the main load-bearing matrix component, contributes significantly to the biomechanical strength of the tissue. This study investigates the relationship between collagen content, collagen cross-links, and biomechanical behavior in human aortic heart valve leaflets and in tissue-engineered constructs. In the main loading direction (circumferential) of native valve leaflets, a significant positive linear correlation between modulus of elasticity and collagen cross-link concentration was found, whereas no correlation between modulus of elasticity and collagen content was found. Similar findings were observed in tissue-engineered constructs, where cross-link concentration was higher for dynamically strained constructs then for statically cultured controls. These findings suggest a dominant role for collagen cross-links over collagen content with respect to biomechanical tissue behavior in human heart valve leaflets. They further suggest that dynamic tissue straining in tissue engineering protocols can enhance cross-link concentration and biomechanical function.
引用
收藏
页码:1501 / 1511
页数:11
相关论文
共 47 条
[31]   Tissue engineering of human heart valve leaflets: A novel bioreactor for a strain-based conditioning approach [J].
Mol, A ;
Driessen, NJB ;
Rutten, MCM ;
Hoerstrup, SP ;
Bouten, CVC ;
Baaijens, FPT .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (12) :1778-1788
[32]   Fibrin as a cell carrier in cardiovascular tissue engineering applications [J].
Mol, A ;
van Lieshout, MI ;
Veen, CGD ;
Neuenschwander, S ;
Hoerstrup, SP ;
Baaijens, FPT ;
Bouten, CVC .
BIOMATERIALS, 2005, 26 (16) :3113-3121
[33]   The relevance of large strains in functional tissue engineering of heart valves [J].
Mol, A ;
Bouten, CVC ;
Zünd, G ;
Günter, CI ;
Visjager, JF ;
Turina, MI ;
Baaijens, FPT ;
Hoerstrup, SP .
THORACIC AND CARDIOVASCULAR SURGEON, 2003, 51 (02) :78-83
[34]   Cardiovascular tissue engineering [J].
Rabkin, E ;
Schoen, FJ .
CARDIOVASCULAR PATHOLOGY, 2002, 11 (06) :305-317
[35]  
Robins SP, 1996, CLIN CHEM, V42, P1621
[36]   A small angle light scattering device for planar connective tissue microstructural analysis [J].
Sacks, MS ;
Smith, DB ;
Hiester, ED .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (04) :678-689
[37]  
Sacks MS, 1998, J BIOMED MATER RES, V41, P131, DOI 10.1002/(SICI)1097-4636(199807)41:1<131::AID-JBM16>3.0.CO
[38]  
2-Q
[39]   AORTIC-VALVE HISTOLOGY AND ITS RELATION WITH MECHANICS - PRELIMINARY-REPORT [J].
SAUREN, AAHJ ;
KUIJPERS, W ;
VANSTEENHOVEN, AA ;
VELDPAUS, FE .
JOURNAL OF BIOMECHANICS, 1980, 13 (02) :97-104
[40]   Comparative study of cellular and extracellular matrix composition of native and tissue engineered heart valves [J].
Schenke-Layland, K ;
Riemann, I ;
Opitz, F ;
König, K ;
Halbhuber, KJ ;
Stock, UA .
MATRIX BIOLOGY, 2004, 23 (02) :113-125