Morphine pharmacokinetics after pulmonary administration from a novel aerosol delivery system

被引:55
作者
Ward, ME
Woodhouse, A
Mather, LE [1 ]
Farr, SJ
Okikawa, JK
Lloyd, P
Schuster, JA
Rubsamen, RM
机构
[1] Univ Sydney, Royal N Shore Hosp, Dept Anaesthesia & Pain Management, St Leonards, NSW 2065, Australia
[2] Aradigm Corp, Hayward, CA USA
关键词
D O I
10.1016/S0009-9236(97)90079-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Successful pharmacotherapy of pain often depends on the mode of drug delivery. A novel, unit dose, aqueous aerosol delivery system (AERx Pulmonary Drug Delivery System) was used to examine the feasibility of the pulmonary route for the noninvasive systemic administration of morphine. Methods: The study had two parts: (1) a dose-ranging study in four subjects with three consecutive aerosolized doses of 2.2, 4.4, and 8.8 mg (nominal) morphine sulfate pentahydrate at 40-minute intervals, and (2) a crossover study, on separate days, in six subjects with 4.4 mg (nominal) aerosolized morphine sulfate administered over 2.1 minutes on three occasions and intravenous infusions of 2 and 4 mg over 3 minutes. Subjects were healthy volunteers from 19 to 34 years old. Arterial blood was sampled for a total of 6 hours and plasma morphine concentrations were measured by gas chromatography-mass spectrometry. Results: In part 1, plasma morphine concentrations were proportional to dose. In part 2, the mean I SD peak plasma concentration (C-max) occurred at 2.7 +/- 0.8 minutes after the aerosol dose, with mean values for C-max of 109 +/- 85, 165 +/- 22, and 273 +/- 114 ng/ml for the aerosol and 2 and 4 mg intravenous doses, respectively. The bioavailability [AUC(0-360 min)] of aerosol-delivered morphine was approximately 100% relative to intravenous infusion, with similar intersubject variability in AUC for both routes (coefficient of variation < 30%). Conclusion: The time courses of plasma morphine concentrations after pulmonary delivery by the AERx system and by intravenous infusions were similar. This shows the utility of the pulmonary route in providing a noninvasive method for the rapid and reproducible systemic administration of morphine if an appropriate aerosol drug delivery system is used.
引用
收藏
页码:596 / 609
页数:14
相关论文
共 20 条
[1]  
*AER CONS STAT, 1991, CHEST, V100, P1106
[2]   ABSORPTION AND BIOAVAILABILITY OF NEBULIZED MORPHINE [J].
CHRUBASIK, J ;
WUST, H ;
FRIEDRICH, G ;
GELLER, E .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (02) :228-230
[3]  
Chrubasik J, 1987, ANESTH ANALG, V66, pS29
[4]  
Chrubasik S, 1993, ADV PAIN THERAPY 2, P151
[5]   PATIENT-CONTROLLED ANALGESIC THERAPY .4. PHARMACOKINETICS AND ANALGESIC PLASMA-CONCENTRATIONS OF MORPHINE [J].
DAHLSTROM, B ;
TAMSEN, A ;
PAALZOW, L ;
HARTVIG, P .
CLINICAL PHARMACOKINETICS, 1982, 7 (03) :266-279
[6]  
FARR SJ, 1996, RESPIRATORY DRUG DEL, V5, P175
[7]   Highly sensitive gas chromatographic mass spectrometric method for morphine determination in plasma that is suitable for pharmacokinetic studies [J].
Fryirs, B ;
Dawson, M ;
Mather, LE .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01) :51-57
[8]   MORPHINE PHARMACOKINETICS AND METABOLISM IN HUMANS - ENTEROHEPATIC CYCLING AND RELATIVE CONTRIBUTION OF METABOLITES TO ACTIVE OPIOID CONCENTRATIONS [J].
HASSELSTROM, J ;
SAWE, J .
CLINICAL PHARMACOKINETICS, 1993, 24 (04) :344-354
[9]   INHALED NEBULIZED FENTANYL FOR POSTOPERATIVE ANALGESIA [J].
HIGGINS, MJ ;
ASBURY, AJ ;
BRODIE, MJ .
ANAESTHESIA, 1991, 46 (11) :973-976
[10]   Systemic absorption of nebulized morphine compared with oral morphine in healthy subjects [J].
Masood, AR ;
Thomas, SHL .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1996, 41 (03) :250-252