Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples

被引:47
作者
Inoue, K [1 ]
Kawaguchi, M [1 ]
Okada, F [1 ]
Yoshimura, Y [1 ]
Nakazawa, H [1 ]
机构
[1] Hoshi Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Shinagawa Ku, 2-4-41 Ebara, Tokyo 1428501, Japan
关键词
di(2-ethylhexyl); phthalate; DEHP; mono(2-ethylhexyl); MEHP; LC-MS; column switching; on-line extraction; blood;
D O I
10.1007/s00216-002-1709-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method based on column-switching high-performance liquid chromatography-electrospray mass spectrometry (LC-MS) coupled with an on-line extraction column containing conjugated avidin has been developed for direct injection analysis of di(2-ethylhexyl) phthalate (DEHP) and its metabolite, mono(2-ethylhexyl) phthalate (MEHP), in blood samples. The sample preparation for on-line extraction involved the mixing of blood samples with internal standards, DEHP-d(4) and MEHP-d(4), in LC glass vials. A linear response was found for column-switching LC-MS when tests were conducted within the validated range of 25 to 1000 ng mL(-1) for DEHP and 5 to 1000 ng mL-1 for MEHP, with correlation coefficients (r) greater than 0.999. In addition, the recoveries of DEHP and MEHP from human plasma were calculated by using this method with on-line extraction, yielding recoveries of up to 91.2% (RSD<5%). We measured the background levels of DEHP and MEHP in six human plasma samples from healthy volunteers and three fetal bovine serum samples for cell-line culture. DEHP and MEHP were not detected in all human plasma samples (N.D. is <25 ng mL(-1) for DEHP, and N.D. is <5.0 ng mL(-1) for MEHP). In contrast, high DEHP contamination of commercially available fetal bovine serum samples was found by this method.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 29 条
[1]   Quantitative detection of eight phthalate metabolites in human urine using HPLC-APCI-MS/MS [J].
Blount, BC ;
Milgram, KE ;
Silva, MJ ;
Malek, NA ;
Reidy, JA ;
Needham, LL ;
Brock, JW .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4127-4134
[2]   Levels of seven urinary phthalate metabolites in a human reference population [J].
Blount, BC ;
Silva, MJ ;
Caudill, SP ;
Needham, LL ;
Pirkle, JL ;
Sampson, EJ ;
Lucier, GW ;
Jackson, RJ ;
Brock, JW .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (10) :979-982
[3]  
Brock JW, 2002, B ENVIRON CONTAM TOX, V68, P309, DOI [10.1007/s00128-001-0255-z, 10.1007/s001280255]
[4]   Chromatographic fractionation and analysis by mass spectrometry of conjugated metabolites of bis(2-ethylhexyl)phthalate in urine [J].
Egestad, B ;
Green, G ;
Sjoberg, P ;
KlassonWehler, E ;
Gustafsson, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 677 (01) :99-109
[5]  
Fischer FP, 1998, PERITON DIALYSIS INT, V18, P620
[6]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE PLASTICIZER DI(2-ETHYLHEXYL) PHTHALATE (DEHP) IN PVC PLASTICS [J].
FUNG, YS ;
TANG, ASK .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :721-723
[7]   Determination of fluoxetine enantiomers in rat plasma by pre-column fluorescence derivatization and column-switching high-performance liquid chromatography [J].
Guo, XJ ;
Fukushima, T ;
Li, FM ;
Imai, K .
ANALYST, 2002, 127 (04) :480-484
[8]   Investigation of the release behavior of diethylhexyl phthalate from the polyvinyl-chloride tubing for intravenous administration [J].
Hanawa, T ;
Muramatsu, E ;
Asakawa, K ;
Suzuki, M ;
Tanaka, M ;
Kawano, K ;
Seki, T ;
Juni, K ;
Nakajima, S .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2000, 210 (1-2) :109-115
[9]   Phthalate esters detected in various water samples and biodegradation of the phthalates by microbes isolated from river water [J].
Hashizume, K ;
Nanya, J ;
Toda, C ;
Yasui, T ;
Nagano, H ;
Kojima, N .
BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (02) :209-214
[10]   The clinical effects of plasticizers, antioxidants, and other contaminants in medical polyvinylchloride tubing during respiratory and non-respiratory exposure [J].
Hill, SS ;
Shaw, BR ;
Wu, AHB .
CLINICA CHIMICA ACTA, 2001, 304 (1-2) :1-8