CT techniques for imaging the lung: recommendations for multislice and single slice computed tomography

被引:17
作者
Aziz, ZA
Padley, SP
Hansell, DM
机构
[1] Royal Brompton Hosp, Dept Radiol, London SW3 6NP, England
[2] Chelsea & Westminster Hosp, Dept Radiol, London SW10 9NH, England
关键词
multislice computed tomography; single slice computed tomography; lung; protocols;
D O I
10.1016/j.ejrad.2004.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of multislice computed tomography (MSCT) has provided the thoracic radiologist with a powerful tool with which to image the lungs. Enthusiasm for new protocols should be tempered with concerns over the potential increase in radiation dose, and before older protocols are abandoned there should be good evidence that newer protocols are objectively superior. Ultimately, the best protocol is one that provides the most relevant clinical information at the lowest dose possible. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:119 / 136
页数:18
相关论文
共 100 条
[41]  
Lawler Leo P, 2002, Curr Probl Diagn Radiol, V31, P115, DOI 10.1067/cdr.2002.125779
[42]   Early bronchiolitis obliterans following lung transplantation: Accuracy of expiratory thin-section CT for diagnosis [J].
Lee, ES ;
Gotway, MB ;
Reddy, GP ;
Golden, JA ;
Keith, FM ;
Webb, WR .
RADIOLOGY, 2000, 216 (02) :472-477
[43]   CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT [J].
LEE, KS ;
PRIMACK, SL ;
STAPLES, CA ;
MAYO, JR ;
ALDRICH, JE ;
MULLER, NL .
RADIOLOGY, 1994, 191 (03) :669-673
[44]   Bronchiolitis obliterans after lung transplantation - Detection using expiratory HRCT [J].
Leung, AN ;
Fisher, K ;
Valentine, V ;
Girgis, RE ;
Berry, GJ ;
Robbins, RC ;
Theodore, J .
CHEST, 1998, 113 (02) :365-370
[45]   Spiral CT of the thorax in daily practice: Optimization of technique [J].
Leung, AN .
JOURNAL OF THORACIC IMAGING, 1997, 12 (01) :2-10
[46]   CHRONIC DIFFUSE INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC-ACCURACY OF HIGH-RESOLUTION AND CONVENTIONAL CT [J].
LEUNG, AN ;
STAPLES, CA ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) :693-696
[47]   Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings [J].
Li, F ;
Sone, S ;
Abe, H ;
MacMahon, H ;
Armato, SG ;
Doi, K .
RADIOLOGY, 2002, 225 (03) :673-683
[48]   Expiratory CT scans for chronic airway disease: Correlation with pulmonary function test results [J].
Lucidarme, O ;
Coche, E ;
Cluzel, P ;
Mourey-Gerosa, I ;
Howarth, N ;
Grenier, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :301-307
[49]   Evaluation of air trapping at CT: Comparison of continuous-versus suspended-expiration CT techniques [J].
Lucidarme, O ;
Grenier, PA ;
Cadi, M ;
Mourey-Gerosa, I ;
Benali, K ;
Cluzel, P .
RADIOLOGY, 2000, 216 (03) :768-772
[50]   Bronchiectasis: Comparative assessment with thin-section CT and helical CT [J].
Lucidarme, O ;
Grenier, P ;
Coche, E ;
Lenoir, S ;
Aubert, B ;
Beigelman, C .
RADIOLOGY, 1996, 200 (03) :673-679