Speciation of Cr(III) and Cr(VI) after column solid phase extraction on Amberlite XAD-2010

被引:61
作者
Bulut, V. N.
Duran, C.
Tufekci, M.
Elci, L.
Soylak, M. [1 ]
机构
[1] Erciyes Univ, Fac Art & Sci, Dept Chem, TR-38039 Kayseri, Turkey
[2] Karadeniz Tech Univ, Giresun Fac Sci & Arts, Dept Chem, TR-28049 Giresun, Turkey
[3] Karadeniz Tech Univ, Fac Sci & Arts, Dept Chem, TR-61080 Trabzon, Turkey
[4] Pamukkale Univ, Fac Art & Sci, Dept Chem, TR-20020 Denizli, Turkey
关键词
speciation; chromium; solid-phase extraction; amberlite XAD-2010; atomic absorption spectrometry;
D O I
10.1016/j.jhazmat.2006.08.074
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A speciation procedure for Cr(III) and Cr(VI) based on column solid phase extraction on Amberlite XAD-2010 and flame atomic absorption spectrometry combination. Cr(VI) was quantitatively recovered on Amberlite XAD-2010 resin at pH range of 2.0-3.0 as its diethyldithiocarbamate complex, while the recoveries of Cr(III) was below 5%. The influences of the various parameters including amounts of the reagents, eluent type and its volume, sample volume, etc., on the quantitative recoveries were examined. The interference of matrix and coexistent elements for method were studied. The detection limit (corresponding to three times the standard deviation of the blank) and the enrichment factor for Cr(VI) were found to be 1.28 mu g/L and 25, respectively. To verify the accuracy of the method, drinking water certified reference material (CRM-TMDW-500) was analyzed and the results obtained were in good agreement with the certified value. The proposed method has been successfully applied to the speciation of Cr(III) and Cr(VI) in water samples and preconcentration of total chromium in environmental samples. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 29 条
[1]  
Abliz S, 2005, SPECTROSC SPECT ANAL, V25, P2082
[2]   Introduction of hydrogen peroxide as an oxidant in flow injection analysis: speciation of Cr(III) and Cr(VI) [J].
Andersen, JET .
ANALYTICA CHIMICA ACTA, 1998, 361 (1-2) :125-131
[3]   Preconcentration and determination of lead, cadmium and nickel from water samples using a polyethylene glycol dye immobilized on poly(hydroxyethylmethacrylate) microspheres [J].
Arpa, Cigdem ;
Bektas, Sema .
ANALYTICAL SCIENCES, 2006, 22 (07) :1025-1029
[4]  
Bantrjee D, 2006, J INDIAN CHEM SOC, V83, P479
[5]   Speciation of Cr(III) and Cr(VI) by means of melamine-urea-formaldehyde resin and FAAS [J].
Demirata, B .
MIKROCHIMICA ACTA, 2001, 136 (3-4) :143-146
[6]   PRECONCENTRATION OF TRACE-METALS IN RIVER WATERS BY THE APPLICATION OF CHELATE ADSORPTION ON AMBERLITE XAD-4 [J].
ELCI, L ;
SOYLAK, M ;
DOGAN, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :175-178
[7]   Preconcentration and Extraction of Copper on Activated Carbon Using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole [J].
Ghaedi, Mehrorang ;
Ahmadi, Farshid ;
Karimi, Hajir ;
Gharaghani, Shiva .
JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2006, 50 (01) :23-31
[8]  
Kargosha K, 2004, ASIAN J SPECTROSC, V8, P101
[9]   Solid phase extraction of lead on octadecyl bonded silica membrane disk modified with Cyanex302 and determination by flame atomic absorption spectrometry [J].
Karve, Manjusha ;
Rajgor, Reeta V. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) :607-613
[10]  
Landgraf W., 2003, DRUG DELIVERY TECHNO, V3, P1