Fatigue and repair in bone

被引:33
作者
Schaffler, MB [1 ]
Jepsen, KJ [1 ]
机构
[1] CUNY Mt Sinai Sch Med, Dept Orthopaed, Orthopaed Res Lab, New York, NY 10029 USA
关键词
D O I
10.1016/S0142-1123(00)00053-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Bone fatigue has been shown to occur at strain magnitudes comparable to those measured on living bones in the physiological loading environment during vigorous activity in animals and humans. At these strain magnitudes, the fatigue life to failure for compact bone is extremely long. However, significant amounts of fatigue damage occur throughout the loading history.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 65 条
[1]  
AGARWAL BD, 1980, ANAL PERFORMANCE FIB
[2]   Intracortical remodeling in adult rat long bones after fatigue loading [J].
Bentolila, V ;
Boyce, TM ;
Fyhrie, DP ;
Drumb, R ;
Skerry, TM ;
Schaffler, MB .
BONE, 1998, 23 (03) :275-281
[3]   FRACTURES OF ALLOGRAFTS - FREQUENCY, TREATMENT, AND END-RESULTS [J].
BERREY, BH ;
LORD, CF ;
GEBHARDT, MC ;
MANKIN, HJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (06) :825-833
[4]   Damage type and strain mode associations in human compact bone bending fatigue [J].
Boyce, TM ;
Fyhrie, DP ;
Glotkowski, MC ;
Radin, EL ;
Schaffler, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (03) :322-329
[5]  
Bronckers ALJJ, 1996, J BONE MINER RES, V11, P1281
[6]  
BUJA LM, 1993, ARCH PATHOL LAB MED, V117, P1208
[7]   Bone microdamage acid skeletal fragility in osteoporotic and stress fractures [J].
Burr, DB ;
Forwood, MR ;
Fyhrie, DP ;
Martin, B ;
Schaffler, MB ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :6-15
[8]   In vivo measurement of human tibial strains during vigorous activity [J].
Burr, DB ;
Milgrom, C ;
Fyhrie, D ;
Forwood, M ;
Nyska, M ;
Finestone, A ;
Hoshaw, S ;
Saiag, E ;
Simkin, A .
BONE, 1996, 18 (05) :405-410
[9]   BONE REMODELING IN RESPONSE TO INVIVO FATIGUE MICRODAMAGE [J].
BURR, DB ;
MARTIN, RB ;
SCHAFFLER, MB ;
RADIN, EL .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :189-&
[10]   VALIDITY OF THE BULK-STAINING TECHNIQUE TO SEPARATE ARTIFACTUAL FROM INVIVO BONE MICRODAMAGE [J].
BURR, DB ;
STAFFORD, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) :305-308