Improved statistical power of the multilinear reference tissue approach to the quantification of neuroreceptor ligand binding by regularization

被引:12
作者
Buchert, R
Wilke, F
van den Hoff, J
Mester, J
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Nucl Med, D-20246 Hamburg, Germany
[2] PET Ctr, Rossendorf, Germany
关键词
PET; modeling; linear regression; reference tissue method; regularization;
D O I
10.1097/01.WCB.0000060565.21994.07
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A multilinear reference tissue approach has been widely used recently for the assessment of neuroreceptor-ligand interactions with positron emission tomography. The authors analyzed this "multilinear method" with respect to its sensitivity to statistical noise, and propose regularization procedures that reduce the effects of statistical noise. Computer simulations and singular value decomposition of its operational equation were used to investigate the sensitivity of the multilinear method to statistical noise. Regularization was performed by truncated singular value decomposition, Tikhonov-Phillips regularization, and by imposing boundary constraints on the rate constants. There was a significant underestimation of distribution volume ratios. Singular value decomposition showed that the bias was caused by statistical noise. The regularization procedures significantly increased the test-retest stability. The bias could be reduced by applying linear constraints on the rate constants based on their normal range. Underestimation of distribution volume ratios by the multilinear method is caused by its sensitivity to statistical noise. Statistical power in the discrimination of different groups of subjects can be significantly improved by regularization procedures without introducing additional bias. Correct distribution volume ratios can be obtained by imposing physiologic constraints on the rate constants.
引用
收藏
页码:612 / 620
页数:9
相关论文
共 27 条
[1]  
Acton PD, 2001, J NUCL MED, V42, P1556
[2]  
Buchert R, 2003, J NUCL MED, V44, P375
[3]   Evaluation of serotonergic transporters using PET and [11C](+)McN-5652:: Assessment of methods [J].
Buck, A ;
Gucker, PM ;
Schönbächler, RD ;
Arigoni, M ;
Kneifel, S ;
Vollenweider, FX ;
Ametamey, SM ;
Burger, C .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (02) :253-262
[4]  
CARSON RE, 1993, PET PARAMETER ESTIMA, P499
[5]  
deBoor Carl, 1987, PRACTICAL GUIDE SPLI
[6]   A STUDY ON STATISTICALLY RELIABLE AND COMPUTATIONALLY EFFICIENT ALGORITHMS FOR GENERATING LOCAL CEREBRAL BLOOD-FLOW PARAMETRIC IMAGES WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, DG ;
WANG, ZZ ;
HUANG, SC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :182-188
[7]  
Hansen P., 1998, Rank-Deficient and Discrete Ill-Posed Problems
[8]  
Hansen P. C., 1994, Numerical Algorithms, V6, P1, DOI 10.1007/BF02149761
[9]   Strategies to improve neuroreceptor parameter estimation by linear regression analysis [J].
Ichise, M ;
Toyama, H ;
Innis, RB ;
Carson, RE .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (10) :1271-1281
[10]  
Ichise M, 1996, J NUCL MED, V37, P513