Reversal of flow during carotid artery stenting: use of the Parodi antiembolism system

被引:15
作者
Grunwald, Iris Q.
Papanagiotou, Panagiotis
Struffert, Tobias
Politi, Maria
Krick, Christoph
Romaike, Bernd F. M.
Ahlhelm, Frank
Reith, Wolfgang
机构
[1] Univ Hosp Saarland, Clin Diagnost & Intervent Neuroradiol, D-66421 Homburg, Germany
[2] Univ Saarland, Dept Neuropathol, D-6650 Homburg, Germany
关键词
carotid stenting flow reversal; proximal protection device; cerebral protection; embolic protection filters;
D O I
10.1007/s00234-006-0178-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction To evaluate the flow reversal efficacy of the Parodi antiembolism system ( PAES) in the prevention of distal emboli during carotid stenting. Methods A total of 90 patients were treated for internal carotid artery (ICA) stenosis with a stent device. A PAES device was used in 31 symptomatic and 5 asymptomatic patients ( total 36 patients) with ICA stenosis, and 54 patients were stented without any protection device. Diffusion-weighted (DW) imaging was performed before and after stenting. Results In the group without PAES protection, 23 out of 54 patients showed new lesions on DW images after stenting. Of the lesions seen, 147 (2.72 lesions/patient) were in the vessel-dependent area. In the group with protection, 19 out of 36 patients had new lesions, and only 34 (0.94 lesions/ patient) were noted in the vessel-dependent area. The number of new lesions in the nondependent vessel area did not differ if a protection system was used (P= 0.671). The use of PAES led to a significant reduction ( P= 0.024) in the incidence of the most frequently seen lesions ( size < 2 mm). The stroke death rate was 3.3% overall, 3.7% in the group without protection device, and 2.7% in the PAES group. There were no permanent neurological deficits after 3 months. Conclusion The PAES is a safe and effective tool to reduce the incidence of embolic complications during carotid stenting. Older patients and patients with higher grade stenosis seem to profit more.
引用
收藏
页码:237 / 241
页数:5
相关论文
共 14 条
[1]   Silent cerebral ischemia detected by diffusion-weighted MRI after carotid endarterectomy [J].
Barth, A ;
Remonda, L ;
Lövblad, KO ;
Schroth, G ;
Seiler, RW .
STROKE, 2000, 31 (08) :1824-1828
[2]   Internal carotid artery stent placement without emboli protection:: Results and long-term outcome [J].
Bibl, D ;
Lampl, C ;
Biberhofer, I ;
Kerschner, K ;
Kypta, A ;
Bergmann, J ;
Kaindlstorfer, A ;
Röper, C ;
Yazdi, K ;
Engleder, C ;
Hofmann, R ;
Deibl, M ;
Leisch, F ;
Ransmayr, G .
NEUROLOGY, 2005, 65 (01) :132-134
[3]   Cognitive changes after carotid artery stenting [J].
Grunwald, I. Q. ;
Supprian, T. ;
Politi, M. ;
Struffert, T. ;
Falkai, P. ;
Krick, C. ;
Backens, M. ;
Reith, W. .
NEURORADIOLOGY, 2006, 48 (05) :319-323
[4]  
Henry M, 1999, J ENDOVASC SURG, V6, P321, DOI 10.1583/1074-6218(1999)006<0321:CSWCPF>2.0.CO
[5]  
2
[6]   Alterations of neuropsychological function and cerebral glucose metabolism after cardiac surgery are not related only to intraoperative microembolic events [J].
Jacobs, A ;
Neveling, M ;
Horst, M ;
Ghaemi, M ;
Kessler, J ;
Eichstaedt, H ;
Rudolf, J ;
Model, P ;
Bönner, H ;
de Vivie, ER ;
Heiss, WD .
STROKE, 1998, 29 (03) :660-667
[7]   Microemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomy [J].
Jordan, WD ;
Voellinger, DC ;
Doblar, DD ;
Plyushcheva, NP ;
Fisher, WS ;
McDowell, HA .
CARDIOVASCULAR SURGERY, 1999, 7 (01) :33-38
[8]  
MARTIN JB, 2001, CIRCULATION, V32, P479
[9]   Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis [J].
Ohki, T ;
Roubin, GS ;
Veith, FJ ;
Iyer, SS ;
Brady, E .
JOURNAL OF VASCULAR SURGERY, 1999, 30 (06) :1034-1042
[10]  
PARODI JC, 2004, P ANN M SOC VASC SUR