Adsorption and reactivity of chlorogenic acid at a hydrophobic carbon ceramic composite electrode: Application for the amperometric detection of hydrazine

被引:40
作者
Salimi, A [1 ]
Hallaj, R [1 ]
机构
[1] Kurdistan Univ, Fac Sci, Dept Chem, Sanandaj, Iran
关键词
sol-gel; carbon ceramic electrode; electroless deposition; chlorogenic acid; hydrazine; amperometry;
D O I
10.1002/elan.200303030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sol-gel technique was used for construction of a carbon composite electrode. The prepared carbon ceramic electrode was modified with electroless deposition of chlorogenic acid for less than 1 min. The adsorbed thin films of chlorogenic acid on carbon composite electrode show one pair of peaks with a surface confined characteristic, which strongly depends on the solution pH, as anticipated for quinone/hydroquinone functionalities. The modified electrode shows highly catalytic activity toward hydrazine electrooxidation at wide pH range (5-11). Also the rotating modified electrode shows excellent analytical performance for amperometric determination of hydrazine. The detection limit, sensitivity, response time and linear dynamic range are 20 nM, 220 nA/muM, 1 second and 0.1 muM-1 mM, respectively. The catalytic rate constant for hydrazine oxidation at the surface of modified electrode was evaluated by cyclic voltammetry and was found to be around 1.5 x 10(3) M(-1)s(-1)in phosphate buffer solution (pH 8). The precision of chronoamperometric measurements was 1-3% for 5 replicate determinations in the concentration range of the linear calibration. The reproducibility of modified CCE was evaluated with 8 successive polishing and modifications and then the anodic peak current was measured (RSD 2%). The advantages of this sensor are excellent catalytic activity, high sensitivity, good reproducibility and simplicity of preparation at short time periods.
引用
收藏
页码:1964 / 1971
页数:8
相关论文
共 42 条
[21]  
Pessôa CA, 2002, ELECTROANAL, V14, P1072, DOI 10.1002/1521-4109(200208)14:15/16<1072::AID-ELAN1072>3.0.CO
[22]  
2-X
[23]  
PLIETH WJ, 1978, ENCY ELECTROCHEMISTR, V8
[24]   Electrochemical characteristics of a cobalt pentacyanonitrosylferrate film on a modified glassy carbon electrode and its catalytic effect on the electrooxidation of hydrazine [J].
Pournaghi-Azar, MH ;
Sabzi, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 543 (02) :115-125
[25]  
Rabinovich L, 2001, ELECTROANAL, V13, P265
[26]   Amperometric detection of dopamine in the presence of ascorbic acid using a nafion coated glassy carbon electrode modified with catechin hydrate as a natural antioxidant [J].
Salimi, A ;
Abdi, K ;
Khayatian, GR .
MICROCHIMICA ACTA, 2004, 144 (1-3) :161-169
[27]   Preparation and electrocatalytic oxidation properties of a nickel pentacyanonitrosylferrate modified carbon composite electrode by two-step sol-gel technique: improvement of the catalytic activity [J].
Salimi, A ;
Abdi, K ;
Khayatiyan, GR .
ELECTROCHIMICA ACTA, 2004, 49 (03) :413-422
[28]   Renewable sol-gel carbon ceramic electrodes modified with a Ru-complex for the amperometric detection of L-cysteine and glutathione [J].
Salimi, A ;
Pourbeyram, S .
TALANTA, 2003, 60 (01) :205-214
[29]   Sol-gel derived carbon ceramic composite electrode containing a ruthenium complex for amperometric detection of insulin at physiological pH [J].
Salimi, A ;
Pourbeyram, S ;
Haddadzadeh, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 542 :39-49
[30]   Renewable-surface sol-gel derived carbon ceramic electrode fabricated by [Ru(bpy)(tpy)Cl]PF6 and its application as an amperometric sensor for sulfide and sulfur oxoanions [J].
Salimi, A ;
Pourbeyrama, S ;
Amini, MK .
ANALYST, 2002, 127 (12) :1649-1656