Large-area microelectrode arrays for recording of neural signals

被引:6
作者
Mathieson, K [1 ]
Kachiguine, S
Adams, C
Cunningham, W
Gunning, D
O'Shea, V
Smith, KM
Chichilnisky, EJ
Litke, AM
Sher, A
Rahman, M
机构
[1] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[2] Univ Calif Santa Cruz, Santa Cruz Inst Particle Phys, Santa Cruz, CA 95064 USA
[3] Salk Inst Biol Studies, La Jolla, CA 92037 USA
关键词
fabrication; in vitro recording; microelectrode arrays; retinal signals;
D O I
10.1109/tns.2004.835873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To understand the neural code, that the retina uses to communicate the visual scene to the brain, large-area microelectrode arrays are needed to record retinal signals simultaneously from many recording sites. This will give a valuable insight into how large biological neural networks (such as the brain) process information, and may also be important in the development of a retinal prosthesis as a potential cure for some forms of blindness. We have used the transparent conductor indium tin oxide to fabricated electrode arrays with approximately 500 electrodes spaced at 60 Am. The fabrication procedures include photolithography, electron-beam lithography, chemical etching and reactive-ion etching. These arrays have been tested electrically using impedance measurements over the range of frequencies important when recording extracellular action potentials (0.1-100 kHz). The data has been compared to a circuit model of the electrode/electrolyte interface. One type of array (512 electrodes) behaves as theory would dictate and exhibits an impedance of 200 kOmega at I kHz. The other array (519 electrodes) has an impedance of 350 kOmega at this frequency, which is higher than predicted by the models. This can perhaps be attributed to the difference in fabrication techniques. The 512-electrode array has been coupled to low-noise amplification circuitry and has recorded signals from a variety of retinal tissues. Example in vitro recordings are shown here.
引用
收藏
页码:2027 / 2031
页数:5
相关论文
共 9 条
[1]  
[Anonymous], PSYCHOANALYSIS CONT
[2]  
Borkholder D. A., 1998, THESIS STANFORD U ST
[3]  
DABROWSKI W, 2003, IEEE NUCL SCI S
[4]   Enzyme sensors prepared by electrodeposition on platinized platinum electrodes [J].
Kim, CS ;
Oh, SM .
ELECTROCHIMICA ACTA, 1996, 41 (15) :2433-2439
[5]  
Kovacs G.T. A., 1994, Enabling Technologies for Cultured Neural Networks, P121, DOI DOI 10.1016/j.jneumeth.2004.03.005
[6]   Large-scale imaging of retinal output activity [J].
Litke, AM ;
Chichilnisky, EJ ;
Dabrowski, W ;
Grillo, AA ;
Grybos, P ;
Kachiguine, S ;
Rahman, M ;
Taylor, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01) :298-307
[7]   Detection of retinal signals using position sensitive microelectrode arrays [J].
Mathieson, K ;
Cunningham, W ;
Marchal, J ;
Melone, J ;
Horn, M ;
Gunning, D ;
Tang, R ;
Wilkinson, C ;
O'Shea, V ;
Smith, KM ;
Litke, A ;
Chichilnisky, E ;
Rahman, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :51-56
[8]   CONCERTED SIGNALING BY RETINAL GANGLION-CELLS [J].
MEISTER, M ;
LAGNADO, L ;
BAYLOR, DA .
SCIENCE, 1995, 270 (5239) :1207-1210
[9]  
SAKARI T, 1983, IEEE T ELECTRON DEV, V30, P183