Plasma-source mass spectrometry for speciation analysis: state-of-the-art

被引:37
作者
Ray, SJ [1 ]
Andrade, F [1 ]
Gamez, G [1 ]
McClenathan, D [1 ]
Rogers, D [1 ]
Schilling, G [1 ]
Wetzel, W [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
elemental speciation; tunable ionization sources; time-of-flight mass spectrometry; electrospray ionization mass spectrometry;
D O I
10.1016/j.chroma.2004.07.107
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Current and emerging capabilities of plasma-source mass spectrometry (PS-MS) as it is employed for elemental speciation analysis are reviewed. Fundamental concepts and their advantageous aspects, experimental conditions, and analytical performance are described and illustrated by recent examples from the literature. Novel instrumentation, techniques, and strategies for inductively-coupled plasma mass spectrometry (ICP-MS), microwave-induced plasma (MIP) mass spectrometry, glow-discharge (GD) mass spectrometry, and electrospray ionization (ESI), among others, are described. The use of ionization sources that provide tunable ionization, others that can be modulated between different sets of operating conditions, and others used in parallel is also examined. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 34
页数:32
相关论文
共 278 条
[31]   Towards an on-chip gas chromatograph: the development of a gas injector and a dc plasma emission detector [J].
Bessoth, FG ;
Naji, OP ;
Eijkel, JCT ;
Manz, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :794-799
[32]   Design and modelling of a modified 2.45 GHz coaxial plasma torch for atomic spectrometry [J].
Bilgic, AM ;
Prokisch, C ;
Broekaert, JAC ;
Voges, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (05) :773-777
[33]   Detection and characterization of zinc- and cadmium-binding proteins in Escherichia coli by gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry [J].
Binet, MRB ;
Ma, RL ;
McLeod, CW ;
Poole, RK .
ANALYTICAL BIOCHEMISTRY, 2003, 318 (01) :30-38
[34]   Mass spectrum measurement using a one-dimensional focal plane detector [J].
Birkinshaw, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) :195-209
[35]   Calibration errors due to variations in peak characteristics in the measurement of transient signals by inductively coupled plasma-scanning mass spectrometry [J].
Björn, E ;
Baxter, DC ;
Frech, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) :1582-1588
[36]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[37]   ION-MOLECULE CLUSTERS INVOLVING DOUBLY CHARGED METAL-IONS (M2+) [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 102 :251-267
[38]   Fast and simultaneous determination of tin and mercury species using SPME, multicapillary gas chromatography and MIP-AES detection [J].
Botana, JC ;
Rodríguez, RR ;
Díaz, AMC ;
Ferreira, RAL ;
Torrijos, RC ;
Pereiro, IR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :904-907
[39]   ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se [J].
Boulyga, SF ;
Becker, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :618-623
[40]  
Bouyssiere B, 2003, ADV CHROMATOGR, V42, P107