Development of a novel fluorescent microsphere technique to combine serial cerebral blood flow measurements with histology in the rat

被引:15
作者
De Visscher, G [1 ]
Haseldonckx, M
Flameng, W
Borgers, M
Reneman, RS
van Rossem, K
机构
[1] Univ Maastricht, CARIM, Dept Mol Cell Biol, Maastricht, Netherlands
[2] Catholic Univ Louvain, CEHA, B-3000 Louvain, Belgium
[3] Johnson & Johnson Pharmaceut Res & Dev, Dept ADME TOX, Beerse, Belgium
[4] Johnson & Johnson Pharmaceut Res & Dev, Ctr Excellence Cardiovasc Safety Res, Beerse, Belgium
关键词
cerebral blood flow; CO2; response; fluorescent microspheres; rat; in situ;
D O I
10.1016/S0165-0270(02)00316-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of the study was to evaluate the microsphere technique for the quantitative assessment of regional cerebral blood flow (rCBF) at different time points in the same animal. Yellow-green and red fluorescent microspheres with a diameter of 15 mum were injected into the rat at two different time points via a cannula inserted into the left ventricle of the heart. The reproducibility of the rCBF measurements in normocapnic conditions (n = 7) and the responsiveness of the flow to hypercapnia induced by 7% CO2 (n = 7) was examined. The fluorescent spheres were counted on 100 mum vibratome sections of perfusion-fixed brains and rCBF was calculated. The median total CBF in normocapnic rats was 224 ml/min/100 g for the first microsphere injection and 216 ml/min/100 g for the second one. In the hypercapnic group CBF amounted to 400 ml/min/100 g and after 30 min of normocapnia decreased to 178 ml/min/100 g. No differences between the left and right hemisphere were found and there was no indication that the first injection might have influenced the second one. The described approach allows combining the assessment of rCBF at different time points in physiological or pathological conditions with histological evaluation of related morphological alterations in the same brain region of the same animal. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 21 条
[1]  
ABEL FL, 1993, CIRC SHOCK, V41, P156
[2]  
Austin G E, 1993, Am J Cardiovasc Pathol, V4, P352
[3]   Control of brain temperature during experimental global ischemia in rats [J].
Brambrink, AM ;
Kopacz, L ;
Astheimer, A ;
Noga, H ;
Heimann, A ;
Kempski, O .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 92 (1-2) :111-122
[4]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[5]   Cerebral blood flow assessment with indocyanine green bolus transit detection by near-infrared spectroscopy in the rat [J].
De Visscher, G ;
van Rossem, K ;
Van Reempts, J ;
Borgers, M ;
Flameng, W ;
Reneman, RS .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR AND INTEGRATIVE PHYSIOLOGY, 2002, 132 (01) :87-95
[6]   HEMISPHERIC BLOOD-FLOW IN THE RAT AFTER UNILATERAL COMMON CAROTID OCCLUSION - EVOLUTION WITH TIME [J].
DELEY, G ;
NSHIMYUMUREMYI, JB ;
LEUSEN, I .
STROKE, 1985, 16 (01) :69-73
[7]   Predictors of stroke outcome [J].
Demchuk, AM ;
Buchan, AM .
NEUROLOGIC CLINICS, 2000, 18 (02) :455-+
[8]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[9]   Cerebral vasoconstriction during sustained ventricular tachycardia induces an ischemic stress response of brain tissue in rats [J].
Hagendorff, A ;
Dettmers, C ;
Danos, P ;
Hümmelgen, M ;
Vahlhaus, C ;
Martin, C ;
Heusch, G ;
Lüderitz, B .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1998, 30 (10) :2081-2094
[10]   EVALUATION OF NONRADIOACTIVE, COLORED MICROSPHERES FOR MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS [J].
HALE, SL ;
ALKER, KJ ;
KLONER, RA .
CIRCULATION, 1988, 78 (02) :428-434