Validation of an algorithm for automatic quantification of nucleic acid copy numbers by real-time polymerase chain reaction

被引:36
作者
Wilhelm, J [1 ]
Pingoud, A [1 ]
Hahn, M [1 ]
机构
[1] Univ Giessen, FB 08, Inst Biochem, D-35392 Giessen, Germany
关键词
quantitative real-time PCR; LightCycler; algorithm; fluorescence resonance energy transfer; hybridization probes;
D O I
10.1016/S0003-2697(03)00167-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Real-time quantitative polymerase chain reaction (PCR) with on-line fluorescence detection has become an important technique not only for determination of the absolute or relative copy number of nucleic acids but also for mutation detection, which is usually done by measuring melting curves. Optimum assay conditions have been established for a variety of targets and experimental setups, but only limited attention has been directed to data evaluation and validation of the results. In this work, algorithms for the processing of real-time PCR data are evaluated for several target sequences (p53, IGF-1, PAI-1, Factor VIIc) and compared to the results obtained by standard procedures. The algorithms are implemented in software called SoFAR, which allows fully automatic analysis of real-time PCR data obtained with a Roche LightCycler instrument. The software yields results with considerably increased precision and accuracy of quantifications. This is achieved mainly by the correction of amplification-independent signal trends and a robust fit of the exponential phase of the signal curves. The melting curve data are corrected for signal changes not due to the melting process and are smoothed by fitting cubic splines. Therefore, sensitivity, resolution, and accuracy of melting curve analyses are improved. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 21 条
  • [1] ANALYSIS OF QUANTITATIVE PCR FOR THE DIAGNOSIS OF DELETION AND DUPLICATION CARRIERS IN THE DYSTROPHIN GENE
    ABBS, S
    BOBROW, M
    [J]. JOURNAL OF MEDICAL GENETICS, 1992, 29 (03) : 191 - 196
  • [2] Monitoring hybridization during polymerase chain reaction
    de Silva, D
    Wittwer, CT
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (01): : 3 - 13
  • [3] Real time quantitative PCR
    Heid, CA
    Stevens, J
    Livak, KJ
    Williams, PM
    [J]. GENOME RESEARCH, 1996, 6 (10): : 986 - 994
  • [4] KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS
    HIGUCHI, R
    FOCKLER, C
    DOLLINGER, G
    WATSON, R
    [J]. BIO-TECHNOLOGY, 1993, 11 (09): : 1026 - 1030
  • [5] DETECTION OF SPECIFIC POLYMERASE CHAIN-REACTION PRODUCT BY UTILIZING THE 5'-]3' EXONUCLEASE ACTIVITY OF THERMUS-AQUATICUS DNA-POLYMERASE
    HOLLAND, PM
    ABRAMSON, RD
    WATSON, R
    GELFAND, DH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (16) : 7276 - 7280
  • [6] Knuth D. E., 1981, ART COMPUTER PROGRAM, V2, P116
  • [7] Molecular beacons - Spectral genotyping of human alleles
    Kostrikis, LG
    Tyagi, S
    Mhlanga, MM
    Ho, DD
    Kramer, FR
    [J]. SCIENCE, 1998, 279 (5354) : 1228 - 1229
  • [8] QUANTITATIVE-ANALYSIS OF POLYMERASE CHAIN-REACTION (PCR) PRODUCTS USING PRIMERS LABELED WITH BIOTIN AND A FLUORESCENT DYE
    LANDGRAF, A
    RECKMANN, B
    PINGOUD, A
    [J]. ANALYTICAL BIOCHEMISTRY, 1991, 193 (02) : 231 - 235
  • [9] A new quantitative method of real time reverse transcription polymerase chain reaction assay based on simulation of polymerase chain reaction kinetics
    Liu, WH
    Saint, DA
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 302 (01) : 52 - 59
  • [10] Morrison TB, 1998, BIOTECHNIQUES, V24, P954