Immobilization of glucose oxidase on reagentless ferrocene-containing polythiophene derivative and its glucose sensing application

被引:68
作者
Abasiyanik, M. Fatih [2 ,3 ]
Senel, Mehmet [1 ,3 ]
机构
[1] Fatih Univ, Dept Chem, Fac Arts & Sci, TR-34500 Istanbul, Turkey
[2] Fatih Univ, Fac Engn, Dept Genet & Bioengn, TR-34500 Istanbul, Turkey
[3] Fatih Univ, Bionanotechnol Res Ctr, Biotechnol Res Lab, TR-34500 Istanbul, Turkey
关键词
Redox polymer; Mediator; Ferrocene; Thiophene; Glucose oxidase; Biosensor; ENZYME ELECTRODE; AMPEROMETRIC DETERMINATION; CARBON NANOTUBES; FUNCTIONALIZATION; POLYMERS; MEDIATOR; PYRROLE; SYSTEM;
D O I
10.1016/j.jelechem.2009.11.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel polymer electrode in the form of a thin film was prepared by electrochemical copolymerization of thiophene, thiophene-3-acetic acid, and dicyclopentadienyl iron-1,4-dienylmethyl-2-(thiophen-3-yl)acetate, for fabricating GO(x)-immobilized electrodes for amperometric sensing of glucose. Glucose oxidase was immobilized by covalent binding to the carboxyl groups on the electrode. The catalytic electrochemistry of the enzyme electrode with the copolymer was investigated. The enzyme electrodes act as a mediator between the redox. center of glucose oxidase (GO(x)) and the electrode. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 33 条
[1]   Electrosynthesis of a functional conducting polymer incorporating ferrocene unit from an EDOT-based bithiophenic precursor [J].
Brisset, Hugues ;
Navarro, Aude-Emmanuelle ;
Moggia, Fabrice ;
Jousselme, Bruno ;
Blanchard, Philippe ;
Roncali, Jean .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 603 (01) :149-154
[2]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[3]   Preparation, characterisation and biosensor application of conducting polymers based on ferrocene substituted thiophene and terthiophene [J].
Chen, J ;
Burrell, AK ;
Collis, GE ;
Officer, DL ;
Swiegers, GF ;
Too, CO ;
Wallace, GG .
ELECTROCHIMICA ACTA, 2002, 47 (17) :2715-2724
[4]   Organically modified sol-gel/chitosan composite based glucose biosensor [J].
Chen, X ;
Jia, JB ;
Dong, SJ .
ELECTROANALYSIS, 2003, 15 (07) :608-612
[5]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[6]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[7]  
Eggins B.R., 2002, CHEM SENSORS BIOSENS, P154
[8]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[9]   ENZYME RECOGNITION BY POLYPYRROLE FUNCTIONALIZED WITH BIOACTIVE PEPTIDES [J].
GARNIER, F ;
YOUSSOUFI, HK ;
SRIVASTAVA, P ;
YASSAR, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (19) :8813-8814
[10]  
HIMURO Y, 2005, T MAT RES SOC JPN, V30