Evaluation of Irrigant Flow in the Root Canal Using Different Needle Types by an Unsteady Computational Fluid Dynamics Model

被引:135
作者
Boutsioukis, Christos [1 ,2 ]
Verhaagen, Bram [3 ,4 ]
Versluis, Michel [3 ,4 ]
Kastrinakis, Eleftherios [5 ]
Wesselink, Paul R. [2 ]
van der Sluis, Lucas W. M. [2 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Dent, Dept Endodontol, GR-54006 Thessaloniki, Greece
[2] Acad Ctr Dent Amsterdam, Dept Cariol, NL-1066 EA Amsterdam, Netherlands
[3] Univ Twente, Fac Sci & Technol, Phys Fluids Grp, NL-7500 AE Enschede, Netherlands
[4] Univ Twente, Res Inst Biomed Technol & Tech Med MIRA, NL-7500 AE Enschede, Netherlands
[5] Aristotle Univ Thessaloniki, Sch Engn, Dept Chem Engn, GR-54006 Thessaloniki, Greece
关键词
Computational Fluid Dynamics; irrigation; needle; tip; EX-VIVO; DIMENSIONS; EFFICACY; RATES;
D O I
10.1016/j.joen.2009.12.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to evaluate the effect of needle tip design on the irrigant flow inside a prepared root canal during final irrigation with a syringe using a validated Computational Fluid Dynamics (CFD) model. Methods: A CFD model was created to simulate the irrigant flow inside a prepared root canal. Six different types of 30-G needles, three open-ended needles and three close-ended needles, were tested. Using this CFD model, the irrigant flow in the apical root canal was calculated and visualized. As a result, the streaming velocity, the apical pressure, and the shear stress on the root canal wall were evaluated. Results: The open-ended needles created a jet toward the apex and maximum irrigant replacement. Within this group, the notched needle appeared less efficient in terms of irrigant replacement than the other two types. Within the close-ended group, the side-vented and double side-vented needle created a series of vortices and a less efficient irrigant replacement; the side-vented needle was slightly more efficient. The multi-vented needle created almost no flow apically to its tip, and wall shear stress was concentrated on a limited area, but the apical pressure was significantly lower than the other types. Conclusions: The flow pattern of the open-ended needles was different from the close-ended needles, resulting in more irrigant replacement in front of the open-ended needles but also higher apical pressure. (J Endod 2010;36:875-879)
引用
收藏
页码:875 / 879
页数:5
相关论文
共 23 条
[11]  
Hulsmann M., 2007, Endodontic Topics, V16, P27, DOI [DOI 10.1111/J.1601-1546.2009.00237.X, DOI 10.1111/J.16011546.2009.00237.X]
[12]  
Ingle JI, 2002, ENDODONTIC, P502
[13]   AN IN-VITRO EVALUATION OF THE IRRIGATING CHARACTERISTICS OF ULTRASONIC AND SUBSONIC HANDPIECES AND IRRIGATING NEEDLES AND PROBES [J].
KAHN, FH ;
ROSENBERG, PA ;
GLIKSBERG, J .
JOURNAL OF ENDODONTICS, 1995, 21 (05) :277-280
[14]   FORCES AND EFFICACY IN ENDODONTIC IRRIGATION SYSTEMS [J].
MOSER, JB ;
HEUER, MA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1982, 53 (04) :425-428
[15]   Current challenges and concepts in the preparation of root canal systems: A review [J].
Peters, OA .
JOURNAL OF ENDODONTICS, 2004, 30 (08) :559-567
[16]   EFFECTIVENESS OF ROOT-CANAL IRRIGATION [J].
RAM, Z .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1977, 44 (02) :306-312
[17]   SOLVENT ACTION OF SODIUM HYPOCHLORITE ON PULP TISSUE OF EXTRACTED TEETH [J].
SENIA, ES ;
MARSHALL, FJ ;
ROSEN, S .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 31 (01) :96-+
[18]   Fluid mechanics in the driven cavity [J].
Shankar, PN ;
Deshpande, MD .
ANNUAL REVIEW OF FLUID MECHANICS, 2000, 32 (32) :93-136
[19]  
Tilton JN., 1999, Perry's Chemical Engineer's Handbook, V7, P1
[20]  
Vande Visse J E, 1975, J Endod, V1, P243, DOI 10.1016/S0099-2399(75)80227-5