Combined long- and short-axis myocardial perfusion cardiovascular magnetic resonance

被引:10
作者
Elkington, AG [1 ]
Gatehouse, PD [1 ]
Prasad, SK [1 ]
Moon, JC [1 ]
Firmin, DN [1 ]
Pennell, DJ [1 ]
机构
[1] Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
关键词
cadiovascular magnetic resonance; perfusion; myocardial; segment;
D O I
10.1081/JCMR-200036129
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To date, myocardial perfusion cardiovascular magnetic resonance (CMR) has been reported in single and multiple short-axis slices. Three short-axis planes can assess 16 segments of the standard 17-segment myocardial model, but this approach fails to assess the ventricular apex that requires at least one long-axis plane. We therefore evaluated the feasibility and benefit of combined long- and short-axis perfusion CMR to enable complete 17 segments coverage for comprehensive myocardial perfusion assessment. Methods and Materials: Using a hybrid echo planar imaging (EPI) sequence, we performed rest and adenosine stress first-pass perfusion CMR studies with 3 short-axis (basal, mid, apical) planes, and additional long-axis planes in the same cardiac cycle in a broad range of cardiology patients. Results: Perfusion CMR was performed in 53 consecutive patients using the combined short-long-axis imaging protocol. Twenty-nine of those studied had known or suspected coronary artery disease (CAD), 18 hypertrophic cardiomyopathy, and 6 suspected microvascular perfusion abnormalities. In 39 patients (70%), it was possible to acquire 5 slices at rest and stress including both the horizontal and vertical long axes. In 15 patients (27%), only one long-axis could be acquired, and in 2 patients (5%) only 3 slices (short axis) could be obtained. However, in none of the patients with known or suspected CAD was apical ischemia demonstrated by the long-axis views, despite apical ischemia having been demonstrated with recent SPECT studies in 8 of these patients. Conclusion: Rest-stress myocardial, perfusion CMR is able to achieve complete segmental coverage of the myocardium using the combined short-long axis approach using an EPI sequence in 97% of a long series of consecutive cardiology patients, while maintaining excellent spatial resolution. However, the long-axis views were not found to be able to demonstrate inducible perfusion defects in the apex.
引用
收藏
页码:811 / 816
页数:6
相关论文
共 13 条
[1]  
ABLITT NA, 2002, P 10 ISMRM, P1615
[2]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[3]   Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage [J].
Bertschinger, KM ;
Nanz, D ;
Buechi, M ;
Luescher, TF ;
Marincek, B ;
von Schulthess, GK ;
Schwitter, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :556-562
[4]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]   Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI [J].
Ding, SJ ;
Wolff, SD ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :514-519
[6]   The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. [J].
Kim, RJ ;
Wu, E ;
Rafael, A ;
Chen, EL ;
Parker, MA ;
Simonetti, O ;
Klocke, FJ ;
Bonow, RO ;
Judd, RM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) :1445-1453
[7]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869
[8]   Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease [J].
Nagel, E ;
Klein, C ;
Paetsch, I ;
Hettwer, S ;
Schnackenburg, B ;
Wegscheider, K ;
Fleck, E .
CIRCULATION, 2003, 108 (04) :432-437
[9]   Abnormal subendocardial perfusion in cardiac syndrome X detected by cardiovascular magnetic resonance imaging [J].
Panting, JR ;
Gatehouse, PD ;
Yang, GZ ;
Grothues, F ;
Firmin, DN ;
Collins, P ;
Pennell, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (25) :1948-1953
[10]  
Schwitter J, 2001, CIRCULATION, V103, P2230