Canal enlargement by Er:YAG laser using a cone-shaped irradiation tip

被引:41
作者
Shoji, S [1 ]
Hariu, H [1 ]
Horiuchi, H [1 ]
机构
[1] Tohoku Univ, Sch Dent, Dept Endodont & Periodont, Aoba Ku, Sendai, Miyagi 9808575, Japan
关键词
D O I
10.1097/00004770-200008000-00006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To solve the problem of mechanical instrumentation, we developed a cone-shaped laser irradiation tip. This tip delivers 80% of the energy of the laser laterally and 20% of the energy forward. The tip was equipped with a water nozzle, The aim of this study was to examine the effect of Er:YAG laser irradiation using this tip on root canal enlargement and debridement, As a root canal model, a hole (0.5 x 5 mm) was drilled into a bovine dentin block, The tip was inserted into this hole and moved from the apex to the orifice (45 mm/min), The power of 10 mJ x 10 pps caused enlargement of the canal dimension by 106.5%. 20 and 40 mJ x 10 pps caused enlargements of 116.3 and 118.6%. 30 mJ x 10 pps caused the biggest change (129.8%), Scanning electron microscopic observations indicated that the dentin surface after laser preparation appeared cleaner than that obtained after preparation by drilling. This technique may have the advantage of decreasing the preparation time.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 20 条
[1]   ULTRASONIC DEBRIDEMENT OF ROOT CANALS - AN INSIGHT INTO THE MECHANISMS INVOLVED [J].
AHMAD, M ;
FORD, TRP .
JOURNAL OF ENDODONTICS, 1987, 13 (03) :93-101
[2]   Study of the Nd:YAP laser. Effect on canal cleanliness [J].
Blum, JY ;
Abadie, MJM .
JOURNAL OF ENDODONTICS, 1997, 23 (11) :669-675
[3]   Effect of power settings versus temperature change at the root surface when using multiple fiber sizes with a holmium YAG laser while enlarging a root canal [J].
Cohen, BI ;
Deutsch, AS ;
Musikant, BL ;
Pagnillo, MK .
JOURNAL OF ENDODONTICS, 1998, 24 (12) :802-806
[4]   Effect of power settings on temperature change at the root surface when using a holmium YAG laser in enlarging the root canal [J].
Cohen, BI ;
Deutsch, AS ;
Musikant, BL .
JOURNAL OF ENDODONTICS, 1996, 22 (11) :596-599
[5]   SCANNING ELECTRON-MICROSCOPIC ANALYSIS OF CANAL WALL DENTIN FOLLOWING NEODYMIUM-YTTRIUM-ALUMINUM-GARNET LASER IRRADIATION [J].
DEDERICH, DN ;
ZAKARIASEN, KL .
JOURNAL OF ENDODONTICS, 1984, 10 (09) :428-431
[6]  
Dostalova T, 1997, J Clin Laser Med Surg, V15, P117
[7]   EXPERIMENTAL STUDIES OF THE APPLICATION OF THE ER YAG LASER ON DENTAL HARD SUBSTANCES .1. MEASUREMENT OF THE ABLATION RATE [J].
HIBST, R ;
KELLER, U .
LASERS IN SURGERY AND MEDICINE, 1989, 9 (04) :338-344
[8]   Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: A comparative SEM investigation [J].
Hulsmann, M ;
Rummelin, C ;
Schafers, F .
JOURNAL OF ENDODONTICS, 1997, 23 (05) :301-306
[9]   LOSS CHARACTERISTICS OF POLYIMIDE-COATED SILVER HOLLOW GLASS WAVE-GUIDES FOR THE INFRARED [J].
KATO, Y ;
OSAWA, M ;
MIYAGI, M ;
ABE, S ;
AIZAWA, M ;
ONODERA, S .
ELECTRONICS LETTERS, 1995, 31 (01) :31-32
[10]   A new engine-driven canal preparation system with electronic canal measuring capability [J].
Kobayashi, C ;
Yoshioka, T ;
Suda, H .
JOURNAL OF ENDODONTICS, 1997, 23 (12) :751-754