In vitro studies of temporary vena cava filters

被引:19
作者
Lorch, H [1 ]
Zwaan, M [1 ]
Kulke, C [1 ]
Weiss, HD [1 ]
机构
[1] Univ Lubeck, Dept Radiol, D-23538 Lubeck, Germany
关键词
interventional procedures; experimental; venae cavae; filters; temporary;
D O I
10.1007/s002709900232
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the clot trapping capacity of different temporary vena cava filters in a vena cava model. Methods: A vena cava flow model was built using PVC tubing, a hemodialysis membrane and a pulsatile pump. Blood was imitated by a Dextran 40 solution. Five different temporary vena cava filters and two prototypes were tested using human thrombi. The mechanism of clot capture was observed. Results: Decreasing rank order according to decreasing percentage of clots captured for the 21-mm diameter vena cava model was Cook (C) > Angiocor (A) > Cordis (CD) > Antheor (TF-6) > DIL for thrombi with a diameter of 3 mm and A > C > CD > TF-6 > DIL for 5-mm thrombi. In a cava with diameter of 28 mm, decreasing rank order was C > CD = A > TF-6 > DIL and C > CD = A > DIL > TF-6 for 3- and 5-mm thrombi, respectively. Two new prototypes, the TF-8 and TF-10 filters, achieved better results than the TF-6 filter and were in most conditions comparable to the A and CD filters. In most cases, thrombi were trapped between filter and cava wall. Conclusion: The vena cava flow model demonstrates significant differences in rates of clot capture (range 22%-98%) depending on cava diameter, thrombus size, and filter type.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 14 条
[1]   PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS - FOLLOW-UP OF 7 DESIGNS IN 320 PATIENTS [J].
FERRIS, EJ ;
MCCOWAN, TC ;
CARVER, DK ;
MCFARLAND, DR .
RADIOLOGY, 1993, 188 (03) :851-856
[2]   FATAL PULMONARY-EMBOLISM FROM DEEP LEG-PELVIS VEINS DURING THROMBOLYTIC TREATMENT [J].
GRIMM, W ;
SCHWIEDER, G ;
WAGNER, T .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1990, 115 (31-32) :1183-1187
[3]  
GUNTHER RW, 1988, INTERVENTIONELLE RAD, P258
[4]   IN-VITRO EVALUATION OF VENA-CAVA FILTERS [J].
HAMMER, FD ;
ROUSSEAU, HP ;
JOFFRE, FG ;
SENTENAC, BP ;
TRANVAN, T ;
BARTHELEMY, RP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (06) :869-876
[5]   INFERIOR VENA-CAVA FILTERS - INVITRO COMPARISON OF CLOT TRAPPING AND FLOW DYNAMICS [J].
KATSAMOURIS, AA ;
WALTMAN, AC ;
DELICHATSIOS, MA ;
ATHANASOULIS, CA .
RADIOLOGY, 1988, 166 (02) :361-366
[6]   Temporary cava filter: Effective prophylaxis of pulmonary embolism in venous thromboses in the region of the pelvic vascular system and of the vena cava inferior? [J].
Kunisch, M ;
Rauber, K ;
Bachmann, G ;
Rau, WS .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (06) :523-526
[7]  
MARTIN M, 1990, DEUT MED WOCHENSCHR, V115, P1812
[8]  
MARTIN MB, 1991, SEMIN THROMB HEMOST, V117, P21
[9]  
Mobin-Uddin K, 1969, Am Surg, V35, P889
[10]   COMPARATIVE INVITRO EVALUATION OF THE NITINOL INFERIOR VENA-CAVA FILTER [J].
PALESTRANT, AM ;
PRINCE, M ;
SIMON, M .