Flow injection technique for biochemical analysis with chemiluminescence detection in acidic media

被引:15
作者
Chen, Jing
Fang, Yanjun
机构
[1] Inst Hyg & Environm Med, Tianjin 300050, Peoples R China
[2] Tianjin Normal Univ, Dept Chem, Tianjin 300073, Peoples R China
关键词
flow injection; chemiluminescence;
D O I
10.3390/s7040448
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A review with 90 references is presented to show the development of acidic chemiluminescence methods for biochemical analysis by use of flow injection technique in the last 10 years. A brief discussion of both the chemiluminescence and flow injection technique is given. The proposed methods for biochemical analysis are described and compared according to the used chemiluminescence system.
引用
收藏
页码:448 / 458
页数:11
相关论文
共 90 条
[1]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[2]   Flow-injection chemiluminescent determination of metoclopramide hydrochloride in pharmaceutical formulations and biological fluids using the [Ru(dipy)32+]-permanganate system [J].
Al-Arfaj, NA .
TALANTA, 2004, 62 (02) :255-263
[3]  
Alonso MCS, 2001, ANAL CHIM ACTA, V437, P225
[4]   Permanganate-based chemiluminescence analysis of cefadroxil monohydrate in pharmaceutical samples and biological fluids using flow injection [J].
Aly, FA ;
Alarfaffj, NA ;
Alwarthan, AA .
TALANTA, 1998, 47 (02) :471-478
[5]   Determination of flufenamic acid and mefenamic acid in pharmaceutical preparations and biological fluids using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Aly, FA ;
Al-Tamimi, SA ;
Alwarthan, AA .
ANALYTICA CHIMICA ACTA, 2000, 416 (01) :87-96
[6]   Flow-injection chemiluminometric analysis of some benzamides by their sensitizing effect on the cerium-sulphite reaction [J].
Aly, FA ;
Alarfaj, NA ;
Alwarthan, AA .
TALANTA, 2001, 54 (04) :715-725
[7]   Flow-injection chemiluminometric determination of some phenothiazines in dosage forms and biological fluids [J].
Aly, FA ;
Alarfaj, NA ;
Alwarthan, AA .
ANALYTICA CHIMICA ACTA, 1998, 358 (03) :255-262
[8]   Comparison of soluble manganese(IV) and acidic potassium permanganate chemiluminescence detection using flow injection and sequential injection analysis for the determination of ascorbic acid in Vitamin C tablets [J].
Anastos, N ;
Barnett, NW ;
Hindson, BJ ;
Lenehan, CE ;
Lewis, SW .
TALANTA, 2004, 64 (01) :130-134
[9]   Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :131-139
[10]   Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :151-158